按摩浴缸漏電怎么辦
1、按摩浴缸漏電的原因
①電源線接觸(chu)不良(liang),漏電開關斷電,維修(xiu)方法就是直接檢查、排除接觸(chu)不良(liang),接通電源;
②電(dian)(dian)源、電(dian)(dian)路上(shang)有(you)漏電(dian)(dian)或對(dui)地(di)現象(xiang),維修方法就是(shi)測量電(dian)(dian)源、電(dian)(dian)路及接(jie)地(di)線,排除(chu)漏電(dian)(dian)、對(dui)地(di)的現象(xiang)。
2、按摩浴缸漏電的維護方法
①要(yao)保(bao)證家里的保(bao)護接地線要(yao)完好,接線符合相(xiang)關要(yao)求。
②保(bao)證漏(lou)電保(bao)護斷路器(qi)的(de)工作正常。
③浴(yu)缸(gang)用電器的(de)(de)插座必須是三個(ge)孔的(de)(de),其中一孔是可靠(kao)接地的(de)(de),做到(dao)這幾樣就不怕浴(yu)缸(gang)漏電了(le)。
按摩浴缸常見故障維修
1、普通浴缸常見故障維修
①、浴缸不能進水(shui)(shui):此(ci)問題的解決方案是(shi)(shi)檢查是(shi)(shi)否有(you)水(shui)(shui)源到龍(long)頭處;浴缸龍(long)頭處有(you)水(shui)(shui),則檢查龍(long)頭是(shi)(shi)否有(you)異(yi)物堵(du)塞,有(you)須清除,龍(long)頭壞(huai)則須更換;檢查進出水(shui)(shui)管是(shi)(shi)否有(you)折(zhe)住。
②、浴(yu)缸(gang)漏(lou)水(shui)(shui)維修:浴(yu)缸(gang)噴(pen)嘴(zui)漏(lou)水(shui)(shui)檢查(cha)噴(pen)嘴(zui)是(shi)(shi)否裝好,打(da)膠是(shi)(shi)否密(mi)封(feng)(feng),噴(pen)嘴(zui)與水(shui)(shui)管連(lian)接是(shi)(shi)否緊固,如有(you)漏(lou)水(shui)(shui)要(yao)先旋(xuan)轉式把(ba)水(shui)(shui)管卸掉水(shui)(shui)管用管道膠水(shui)(shui)重新接上;浴(yu)缸(gang)龍(long)頭(tou)處(chu)漏(lou)水(shui)(shui)則先打(da)開龍(long)頭(tou)手柄取(qu)出龍(long)頭(tou)閥芯是(shi)(shi)否損壞(huai)(huai),密(mi)封(feng)(feng)膠圈是(shi)(shi)否破(po)裂(lie)(lie),如有(you)則要(yao)更(geng)換,再檢查(cha)龍(long)頭(tou)體(ti)是(shi)(shi)否有(you)裂(lie)(lie)紋,沙(sha)眼等有(you)則要(yao)更(geng)換龍(long)頭(tou);檢查(cha)去水(shui)(shui)器是(shi)(shi)否連(lian)接好,去水(shui)(shui)管道是(shi)(shi)否有(you)裂(lie)(lie)或堵塞;電機處(chu)漏(lou)水(shui)(shui)則要(yao)檢查(cha)進出水(shui)(shui)管膠圈是(shi)(shi)否損壞(huai)(huai),電機水(shui)(shui)封(feng)(feng)是(shi)(shi)否損壞(huai)(huai),壞(huai)(huai)須更(geng)換。
2、按摩浴缸常見故障維修
①、浴缸不通電或漏電保護開關跳閘:導致按摩浴缸這種故障的第一(yi)種原因是(shi)電(dian)源(yuan)(yuan)線(xian)接(jie)觸不(bu)良,漏(lou)電(dian)開關(guan)斷電(dian),浴缸維(wei)修方(fang)(fang)法是(shi)檢(jian)查、排除接(jie)觸不(bu)良,接(jie)通電(dian)源(yuan)(yuan);第二種原因是(shi)電(dian)源(yuan)(yuan)、電(dian)路(lu)上有漏(lou)電(dian)或(huo)對地(di)現象,浴缸維(wei)修方(fang)(fang)法是(shi)測量電(dian)源(yuan)(yuan)、電(dian)路(lu)及(ji)接(jie)地(di)線(xian),排除漏(lou)電(dian)、對地(di)。
②、不能調(diao)節按(an)摩水力大小:第一(yi)種原(yuan)因是(shi)(shi)(shi)(shi)水泵(beng)吸力不夠,維修方法是(shi)(shi)(shi)(shi)檢查水泵(beng)是(shi)(shi)(shi)(shi)否完(wan)好;第二(er)種原(yuan)因是(shi)(shi)(shi)(shi)空(kong)(kong)氣(qi)調(diao)節閥(fa)不正常,維修方法是(shi)(shi)(shi)(shi)更換空(kong)(kong)氣(qi)調(diao)節閥(fa);第三種原(yuan)因是(shi)(shi)(shi)(shi)噴嘴堵塞,維修方法是(shi)(shi)(shi)(shi)清(qing)除噴嘴雜(za)物。
③、控制面(mian)板不(bu)啟動:第(di)一(yi)種(zhong)原因是電(dian)源(yuan)線沒接好,漏電(dian)開(kai)(kai)關(guan)斷開(kai)(kai),維修(xiu)方(fang)法是檢查電(dian)源(yuan)線,重新接好;第(di)二種(zhong)原因是控制面(mian)板開(kai)(kai)關(guan)失靈,維修(xiu)方(fang)法是更換(huan)面(mian)板。