穩(wen)壓(ya)(ya)(ya)器是使(shi)輸出(chu)電(dian)壓(ya)(ya)(ya)穩(wen)定(ding)的(de)設備。穩(wen)壓(ya)(ya)(ya)器由(you)調壓(ya)(ya)(ya)電(dian)路、控(kong)制電(dian)路、及(ji)伺(si)服電(dian)機等(deng)組成(cheng)。當輸入電(dian)壓(ya)(ya)(ya)或負載變(bian)化時,控(kong)制電(dian)路進行(xing)取樣、比較、放大(da),然后(hou)驅動伺(si)服電(dian)機轉動,使(shi)調壓(ya)(ya)(ya)器碳(tan)刷的(de)位置改變(bian),通(tong)過自動調整線圈匝數比,從而(er)保持(chi)輸出(chu)電(dian)壓(ya)(ya)(ya)的(de)穩(wen)定(ding)。
穩壓(ya)器是一(yi)種能自動(dong)調(diao)整輸出電壓(ya)的供(gong)電電路(lu)或(huo)供(gong)電設(she)備,其作(zuo)用(yong)是將波(bo)動(dong)較(jiao)大和達(da)不到電器設(she)備要求的電源電壓(ya)穩定(ding)(ding)在(zai)它的設(she)定(ding)(ding)值(zhi)范圍內,使各種電路(lu)或(huo)電器設(she)備能在(zai)額定(ding)(ding)工作(zuo)電壓(ya)下正(zheng)常工作(zuo)。
最初的(de)電(dian)(dian)力穩(wen)壓(ya)器是(shi)靠繼(ji)電(dian)(dian)器的(de)跳動(dong)(dong)(dong)(dong)穩(wen)定(ding)電(dian)(dian)壓(ya)的(de)。當電(dian)(dian)網電(dian)(dian)壓(ya)出現波(bo)動(dong)(dong)(dong)(dong)時(shi),電(dian)(dian)力穩(wen)壓(ya)器的(de)自動(dong)(dong)(dong)(dong)糾正電(dian)(dian)路啟動(dong)(dong)(dong)(dong),使內部繼(ji)電(dian)(dian)器動(dong)(dong)(dong)(dong)作。迫使輸出電(dian)(dian)壓(ya)保持在(zai)設定(ding)值(zhi)附近,這種電(dian)(dian)路優點(dian)是(shi)電(dian)(dian)路簡(jian)單,缺點(dian)是(shi)穩(wen)壓(ya)精度不高并且每一次繼(ji)電(dian)(dian)器跳動(dong)(dong)(dong)(dong)換擋,都(dou)會(hui)使供電(dian)(dian)電(dian)(dian)源發生一次瞬時(shi)的(de)中斷并產(chan)生火花干擾。
這對電(dian)(dian)腦設備(bei)的讀寫工(gong)作(zuo)干擾(rao)很大,容易造(zao)成電(dian)(dian)腦出現錯誤信號(hao),嚴重時還會使硬盤損(sun)壞(huai)。
高(gao)質量的小型(xing)穩(wen)(wen)壓(ya)器(qi),大(da)多(duo)采用電機拖動碳刷的方(fang)法穩(wen)(wen)定(ding)電壓(ya),這種穩(wen)(wen)壓(ya)器(qi)對電器(qi)設備產生的干擾很(hen)小穩(wen)(wen)壓(ya)精(jing)度相對較高(gao)。
【詳細>>】
由于部分電器中含有線(xian)圈組(zu)件,在(zai)通電初期(qi)會(hui)(hui)產(chan)生(sheng)(sheng)阻礙電流的(de)(de)渦流,渦流的(de)(de)產(chan)生(sheng)(sheng)既會(hui)(hui)削弱到電器啟動時(shi)(shi)(shi)的(de)(de)瞬(shun)(shun)時(shi)(shi)(shi)電壓,導致啟動緩慢(man),又會(hui)(hui)加強斷路后產(chan)生(sheng)(sheng)的(de)(de)瞬(shun)(shun)時(shi)(shi)(shi)電壓,可能產(chan)生(sheng)(sheng)火花損壞電路。此時(shi)(shi)(shi)便需要一個穩(wen)壓器來保(bao)護電路的(de)(de)正常運行。
穩壓器由調壓電路、控制電路、及伺服電機等組成,當輸入電壓或負載變化時,控制電路進行取樣、比較、放大,然后驅動伺服電機轉動,使調壓器碳刷的位置改變,通過自動調整線圈匝數比,從而保持輸出電壓的穩定。容量較大的穩壓器,還采用電壓補償的原理工作。【詳細>>】
1、穩壓器所標輸(shu)出功(gong)率(lv)是最大(da)功(gong)(gong)率。家用電(dian)器(qi)的標稱(cheng)功(gong)(gong)率是指有功(gong)(gong)功(gong)(gong)率,而冰箱(xiang)、空調、水泵(beng)等(deng)感(gan)性負載在(zai)啟(qi)動瞬時間電(dian)流很大(da),因此電(dian)冰箱(xiang)、空調、水泵(beng)按功(gong)(gong)率×(3~5倍)。
例如:3匹美的空調(220V用電)
1匹等于0.75千瓦×3匹=2.25千瓦×3倍(bei)感性負載啟(qi)動電流=6.75千瓦以上穩壓器(qi)適用。(美的維修裝技師(shi)推薦選用8KVA穩壓器(qi))
2、以專業水電安裝技師及工廠專業電工、工程師和(he)穩(wen)壓器(qi)使用功(gong)率算(suan)法:一般工業(ye)設備(bei)按額定功(gong)率至少乘以2倍以上使用功(gong)率,當使用在具備(bei)電機運轉(zhuan)設備(bei)、大電流啟(qi)動裝置及沖擊性(xing)負載設備上時(shi),應選擇3倍以上容量的穩壓器(qi),以免(mian)啟動電流過(guo)大,供電線(xian)路(lu)降壓而無法(fa)正常工作。
如:某一工廠的汽泵機(380V用電設備)某電(dian)機(ji)功(gong)率(lv)為7.5千瓦,然而它開始運(yun)轉(zhuan)沖擊作功(gong)時浪涌電(dian)流過(guo)到電(dian)機(ji)功(gong)率(lv)的3倍以上,所以必(bi)須選擇(ze)大于其功(gong)率(lv)3倍的穩壓器(qi)。
3、0.5KVA—3KVA穩壓器(qi)選擇輸出電壓110V時(shi),則輸入容量不能超過額定容量的40%,當輸出端需110V和220V同時使用時輸出容量應在額定容量的50%,以免過載。【詳細>>】
購買穩壓器時,建議大家至(zhi)少要選購比實(shi)際功率大三(san)倍的(de)(de)穩壓器,因為(wei)穩壓器在實(shi)際工作中要克服市(shi)電(dian)的(de)(de)浪涌沖擊和感性負載的(de)(de)起動沖擊(如冰箱、空調、馬達和電(dian)動機)。
1、穩(wen)(wen)壓(ya)器(qi)用(yong)(yong)在感性(xing)負(fu)載(zai)(zai)(zai)時,由于(yu)(yu)感性(xing)負(fu)載(zai)(zai)(zai)有較(jiao)大(da)的(de)(de)瞬間起動(dong)電(dian)流(liu),一般約為額定(ding)電(dian)流(liu)的(de)(de)3—5倍(bei)往往超過運行電(dian)流(liu)的(de)(de)9倍(bei)(如電(dian)冰箱(xiang)、空調器(qi)、洗衣(yi)機(ji)(ji)、電(dian)扇、大(da)型空調,印刷機(ji)(ji),空壓(ya)機(ji)(ji),電(dian)梯,水泵等(deng)都屬于(yu)(yu)感性(xing)負(fu)載(zai)(zai)(zai)),所以凡配用(yong)(yong)電(dian)動(dong)機(ji)(ji)、壓(ya)縮機(ji)(ji)電(dian)器(qi)等(deng)感性(xing)負(fu)載(zai)(zai)(zai)的(de)(de)穩(wen)(wen)壓(ya)器(qi),都必須考慮其功率(lv)儲(chu)備(bei),要留(liu)(liu)有余量(liang),就要預(yu)留(liu)(liu)足(zu)夠的(de)(de)余量(liang),避免負(fu)載(zai)(zai)(zai)開機(ji)(ji)時產生的(de)(de)沖擊電(dian)流(liu)對穩(wen)(wen)壓(ya)器(qi)造(zao)成(cheng)即(ji)時的(de)(de)損害。如整(zheng)廠使用(yong)(yong)穩(wen)(wen)壓(ya)器(qi),在啟動(dong)機(ji)(ji)器(qi)時,應避免大(da)功率(lv)感性(xing)負(fu)載(zai)(zai)(zai)同一時間啟動(dong),所以在選(xuan)購穩(wen)(wen)壓(ya)器(qi)時,應有1.5倍(bei)的(de)(de)預(yu)留(liu)(liu)容(rong)量(liang)單機(ji)(ji)配套的(de)(de)預(yu)留(liu)(liu)量(liang)應有3倍(bei)。
2、注(zhu)意市(shi)電(dian)供(gong)電(dian)的(de)(de)電(dian)壓(ya)值,是否超(chao)出(chu)所選購的(de)(de)穩(wen)壓(ya)器規(gui)定的(de)(de)輸(shu)入(ru)電(dian)壓(ya)范圍,三相電(dian)電(dian)壓(ya)有否相差10V以(yi)上
3、在(zai)購機前,要(yao)考慮日后業務擴展,是(shi)否需要(yao)增加(jia)設(she)備(bei),穩(wen)壓(ya)器是(shi)否需要(yao)預(yu)留擴展容(rong)量(liang)
4、無(wu)論是單(dan)機配套或(huo)整廠配套,選購的穩(wen)壓器(qi)(qi)要預(yu)留一(yi)定(ding)的預(yu)留容量,避免穩(wen)壓器(qi)(qi)百(bai)分(fen)百(bai)的負載率,穩(wen)壓器(qi)(qi)的負載率一(yi)般達90%這樣較為(wei)適宜。自動調壓器(qi)(qi)的外(wai)形結構(gou)有臺式、掛壁(bi)式、臺壁(bi)兩用式和落(luo)地式等幾(ji)種(zhong),應(ying)根據安裝放置的位置、主(zhu)要用途(tu),以及安裝能力(li),選擇不(bu)同的款式。
5、業內人士提示,在選擇穩壓器時,還要注意要選擇品牌知名度高的產品,因為這些廠家質量可靠、服務周到;同時廠家是否有良好的售后服務,如產品質量執行三包等,也是消費者應注意的重要因素。【詳細>>】
1、接(jie)(jie)入市電(dian)(按照國(guo)家規(gui)定(ding)的(de)左零右(you)火接(jie)(jie)線標準)
①接入(ru)設(she)備的輸入(ru)導線線徑必(bi)須保(bao)證≥25mm2銅(tong)芯線
②接入設備的輸(shu)入,輸(shu)出線卡鏍絲必(bi)須擰(ning)緊
③輸入、輸出線不得接反(fan)
④設備(bei)前端(duan)不能以漏電保護器代(dai)替空氣開關(guan)
2、接入負載
負載功率(lv)不能超(chao)出穩壓電源的最大功率(lv):例:50KVA.一般負載率(lv)為50KVA×0.8=40KW
①輸出線路(lu)(lu)的(de)所(suo)有線接口必須(xu)接緊,否則會因為電流較大造(zao)成線路(lu)(lu)發熱(re),來影響有效功率。
3、開啟(qi)穩壓電源(嚴(yan)禁先開啟(qi)負載,后開啟(qi)穩壓電源)
①請(qing)保證電(dian)腦顯示器是關閉的情況下開(kai)啟穩壓電(dian)源。
②開(kai)啟之前先測(ce)量輸入電壓值應在304V-456V之間。
③察看機器自帶的輸出電(dian)壓表應為(wei)380V。
4、不要使(shi)用(yong)過(guo)高的(de)負載;
5、請使用足夠的電線;
6、請小心連(lian)接好輸入電(dian)壓(ya)和儀器(qi)設(she)備的輸出;
7、儀器設備與(yu)穩壓器的輸出(chu)電(dian)壓要(yao)統一;
8、請選(xuan)擇好(hao)輸入電壓開(kai)關與電源電壓一樣(yang);
9、如果(guo)保險絲(si)燒壞,請核對負載設(she)備;
10、要(yao)用同一定額(e)的保險(xian)絲,不能使用非額(e)定保險(xian)絲或電(dian)線;
11、安裝在干燥通(tong)風的(de)地方。【詳細>>】
穩(wen)(wen)壓器是(shi)按用(yong)電(dian)設備的要(yao)求提供(gong)穩(wen)(wen)定輸出電(dian)壓的一(yi)種設備。主要(yao)有智能數控型(xing)、自耦調(diao)整(zheng)型(xing)、大功率補償型(xing)、開關型(xing)等種類。
穩(wen)壓器日常保養要注意4點:
1、穩壓器應放置在(zai)通風、干燥、無(wu)陽光直射、無(wu)腐蝕性氣體的室內使(shi)用;
2、穩(wen)壓器選用(yong)的(de)功率(lv)(lv)應大于用(yong)電設(she)備的(de)總功率(lv)(lv);
3、穩(wen)(wen)壓器開關(guan)(guan)不(bu)宜(yi)作設(she)(she)備(bei)的總(zong)開關(guan)(guan)使(shi)用,應先打開穩(wen)(wen)壓器開關(guan)(guan),待(dai)有電源輸出后(hou),再依次從(cong)按功率小(xiao)(xiao)到(dao)大接上(shang)不(bu)同的用電設(she)(she)備(bei),關(guan)(guan)機時(shi)從(cong)大到(dao)小(xiao)(xiao)關(guan)(guan)機,最后(hou)關(guan)(guan)上(shang)穩(wen)(wen)壓器的開關(guan)(guan);
4、穩壓器的(de)開關不宜頻繁開啟(qi),每次開啟(qi)的(de)時間間隔應大于(yu)10秒,否則易造成稱穩壓器誤保(bao)護,甚至于(yu)損壞。
第一、電(dian)(dian)(dian)壓偏高需降壓;當輸入電(dian)(dian)(dian)壓遠遠高于穩壓設備(bei)所承載的(de)額定電(dian)(dian)(dian)壓,這時就會導致穩壓設備(bei)失靈,故而(er)出現電(dian)(dian)(dian)壓不穩;
第(di)二(er)、過(guo)壓保(bao)(bao)護電(dian)路;過(guo)壓保(bao)(bao)護后(hou),LED發光管(guan)亮,從而出現斷電(dian)現象(xiang);
第三、欠(qian)壓(ya)保護(hu)電路;電壓(ya)偏低(di),通過(guo)調壓(ya)器(qi)的(de)調整(zheng)仍(reng)不在范圍內(低(di)于220V),最終導致繼電器(qi)釋(shi)放(fang),即(ji)便有二極管此(ci)時也(ye)管用了,故而(er)出現電壓(ya)不穩。
第四、取樣電(dian)(dian)(dian)壓(ya)與基準電(dian)(dian)(dian)壓(ya);取樣電(dian)(dian)(dian)壓(ya)和基準電(dian)(dian)(dian)壓(ya)接入(ru)電(dian)(dian)(dian)壓(ya)比較(jiao)器輸入(ru)端的規律是:檢測電(dian)(dian)(dian)腦穩壓(ya)器輸出電(dian)(dian)(dian)壓(ya)是否高于額定值(zhi)220V,其正輸入(ru)端接取樣電(dian)(dian)(dian)壓(ya),負輸入(ru)端接基準電(dian)(dian)(dian)壓(ya)。
第五、電(dian)(dian)壓(ya)偏低需要(yao)升壓(ya);若因(yin)輸入電(dian)(dian)壓(ya)偏高或(huo)偏低較(jiao)多(duo),電(dian)(dian)動機拖(tuo)動碳刷轉至極限位置仍(reng)不能使(shi)輸出(chu)電(dian)(dian)壓(ya)回到220V,碳刷架(jia)將(jiang)觸及限位開關,電(dian)(dian)動機斷電(dian)(dian)停轉,以免電(dian)(dian)動機過載(zai)損壞(huai)。
第六、開(kai)機延時(shi)(shi)間(jian)斷控制(zhi);到開(kai)機延時(shi)(shi)結(jie)束(shu)。這(zhe)個過程大約(yue)需要5分鐘。開(kai)機延時(shi)(shi)送電(dian)主要是(shi)為了保護(hu)(hu)空調、電(dian)冰(bing)箱(xiang)等設備的用電(dian)安全,若(ruo)無此需求,可按下快(kuai)啟自(zi)鎖按鈕(niu)AN,此時(shi)(shi)開(kai)機延時(shi)(shi)時(shi)(shi)間(jian)將縮短為2~3秒鐘,開(kai)機延時(shi)(shi)送電(dian)主要是(shi)為了保護(hu)(hu)電(dian)路的用電(dian)安全;