【室內物理環境設計】家(jia)居給排水(shui)系統設計 家(jia)居出(chu)水(shui)入(ru)水(shui)有道
一、室內給排水概述
1.1室內給水
從建筑物內(nei)部結構來說,給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)包括生活給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)、生產給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)、中水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)、消(xiao)防給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)、以及組合給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)。例如自(zi)(zi)(zi)(zi)動排(pai)氣(qi)閥(fa)(fa)就(jiu)是屬于給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)。設(she)有延(yan)(yan)(yan)時(shi)(shi)自(zi)(zi)(zi)(zi)閉閥(fa)(fa)的(de)(de)(de)(de)蹲式大便(bian)器的(de)(de)(de)(de)室內(nei)給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)系(xi)統(tong)(tong)(tong),如學校、旅館、辦公樓等,如果在(zai)(zai)給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)管系(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)最頂(ding)層設(she)有自(zi)(zi)(zi)(zi)閉閥(fa)(fa),最好在(zai)(zai)管系(xi)的(de)(de)(de)(de)最高點增設(she)自(zi)(zi)(zi)(zi)動排(pai)氣(qi)裝置。因為給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)用的(de)(de)(de)(de)延(yan)(yan)(yan)時(shi)(shi)自(zi)(zi)(zi)(zi)閉閥(fa)(fa)能很好地(di)控(kong)制(zhi)水(shui)(shui)(shui)(shui)流,但卻不能很好地(di)控(kong)制(zhi)氣(qi)流。當系(xi)統(tong)(tong)(tong)停水(shui)(shui)(shui)(shui)時(shi)(shi),給(gei)(gei)(gei)水(shui)(shui)(shui)(shui)管內(nei)常(chang)(chang)(chang)積存有大量的(de)(de)(de)(de)空(kong)氣(qi)。系(xi)統(tong)(tong)(tong)恢復(fu)供(gong)水(shui)(shui)(shui)(shui)后,管系(xi)內(nei)空(kong)氣(qi)常(chang)(chang)(chang)會被水(shui)(shui)(shui)(shui)流壓(ya)縮至管系(xi)頂(ding)部而(er)形成一個壓(ya)縮空(kong)氣(qi)區。此時(shi)(shi)有人再按下延(yan)(yan)(yan)時(shi)(shi)自(zi)(zi)(zi)(zi)閉閥(fa)(fa)的(de)(de)(de)(de)按扭時(shi)(shi),則(ze)壓(ya)縮的(de)(de)(de)(de)空(kong)氣(qi)會伴(ban)隨著水(shui)(shui)(shui)(shui)流噴薄而(er)出,常(chang)(chang)(chang)會將便(bian)器內(nei)的(de)(de)(de)(de)污物吹到(dao)地(di)面以上,甚至濺到(dao)入廁者的(de)(de)(de)(de)衣(yi)物上。在(zai)(zai)管系(xi)的(de)(de)(de)(de)最高點設(she)一個自(zi)(zi)(zi)(zi)動排(pai)氣(qi)閥(fa)(fa)則(ze)可有效(xiao)地(di)解(jie)決這一問(wen)題。
2.2室內排水
排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)包(bao)括生(sheng)活(huo)排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong),工(gong)業(ye)廢(fei)水(shui)(shui)(shui)排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong),以(yi)及屋面雨水(shui)(shui)(shui)排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)。這些系(xi)(xi)統(tong)(tong)(tong)中(zhong)包(bao)括了水(shui)(shui)(shui)質處理,水(shui)(shui)(shui)質、水(shui)(shui)(shui)溫、水(shui)(shui)(shui)壓保證及供水(shui)(shui)(shui)、配水(shui)(shui)(shui)、排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)、通(tong)氣等眾多技術(shu)內(nei)(nei)涵。隨著(zhu)社會的(de)(de)(de)進步和(he)科(ke)學得到發(fa)展,室(shi)內(nei)(nei)給排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)在(zai)(zai)不斷派(pai)生(sheng)出各種新(xin)(xin)的(de)(de)(de)子(zi)系(xi)(xi)統(tong)(tong)(tong),新(xin)(xin)技術(shu)、新(xin)(xin)材料日(ri)新(xin)(xin)月(yue)異地涌現(xian)。室(shi)內(nei)(nei)給排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)已成(cheng)為我(wo)國(guo)現(xian)代(dai)化(hua)建設(she)中(zhong)一(yi)支不可忽視的(de)(de)(de)力量,在(zai)(zai)生(sheng)活(huo)中(zhong)起著(zhu)舉足輕重的(de)(de)(de)作用。對于廚房和(he)廁所相鄰的(de)(de)(de)住(zhu)宅(zhai)來說(shuo),如果(guo)廚、廁是(shi)單獨的(de)(de)(de)排(pai)(pai)(pai)(pai)水(shui)(shui)(shui)管系(xi)(xi)統(tong)(tong)(tong),則在(zai)(zai)最(zui)底層為兩系(xi)(xi)統(tong)(tong)(tong)作一(yi)個緊急排(pai)(pai)(pai)(pai)出聯通(tong)。從對目前我(wo)國(guo)居民的(de)(de)(de)生(sheng)活(huo)習慣來說(shuo),下水(shui)(shui)(shui)管道發(fa)生(sheng)堵(du)塞現(xian)象發(fa)生(sheng)的(de)(de)(de)可能性(xing)非常大,也可以(yi)說(shuo)只是(shi)堵(du)的(de)(de)(de)次(ci)數(shu)多與少的(de)(de)(de)問題(ti)。如果(guo)室(shi)內(nei)(nei)設(she)計人員對傳統(tong)(tong)(tong)作法稍(shao)做(zuo)改動,則可在(zai)(zai)很大程(cheng)度上(shang)方便用戶。
二、室內給水設計
2.1生活給水系統
建筑物內應盡量利用(yong)室外管(guan)網的水(shui)(shui)壓(ya)直(zhi)接供水(shui)(shui),當水(shui)(shui)壓(ya)不滿足(zu)要求時設加(jia)壓(ya)裝置,生活水(shui)(shui)池(chi)及(ji)其泵房設在底層,屋頂設水(shui)(shui)箱(xiang),各(ge)配水(shui)(shui)點處的靜(jing)水(shui)(shui)壓(ya)不宜大于0.45MPa,同時(shi)最(zui)高(gao)層水壓不宜小于0.10MPa,水壓大于0.35MPa的(de)(de)(de)人戶管,應設(she)減壓(ya)設(she)施,且(qie)為(wei)了(le)利用外(wai)管網(wang)的(de)(de)(de)水(shui)(shui)(shui)壓(ya),以節省能(neng)耗(hao),一般(ban)以外(wai)管網(wang)能(neng)滿足水(shui)(shui)(shui)壓(ya)要求的(de)(de)(de)樓層為(wei)低(di)壓(ya)區,空調冷卻塔(ta)的(de)(de)(de)補水(shui)(shui)(shui)量一般(ban)均較生活用水(shui)(shui)(shui)量大得多,因此有條件(jian)的(de)(de)(de)宜將冷卻塔(ta)置(zhi)于低(di)壓(ya)區。市(shi)政壓(ya)力不能(neng)滿足要求的(de)(de)(de)給水(shui)(shui)(shui)系(xi)統的(de)(de)(de)BA設計小區每棟單體均設有(you)水(shui)池、水(shui)箱、水(shui)泵,由于數量多(duo),如用傳統的(de)管(guan)理方式務必造(zao)成人力、資源的(de)浪費,給管(guan)理帶來(lai)很多(duo)不(bu)便,一(yi)般設計中采(cai)用BA系統對各個水(shui)池、水(shui)箱、水(shui)泵的(de)運行狀態、故障狀態等進行監視、控制。BA系統(tong)(tong)中的自動抄表系統(tong)(tong)解決(jue)了人工抄表帶來的諸多(duo)不便,更好(hao)地為住戶服務(wu)。給水系統(tong)(tong)的BA設計主要是(shi)通過液位、壓(ya)力、流量等訊號(hao)對加(jia)壓(ya)泵、水池、水箱運行狀態進行監視、控制。
2.2熱水系統
住宅樓熱(re)(re)(re)水(shui)由各自煤氣(qi)、太(tai)陽能、電熱(re)(re)(re)水(shui)器提(ti)供(gong)(gong),公(gong)共建筑熱(re)(re)(re)水(shui)由集中熱(re)(re)(re)水(shui)供(gong)(gong)應系統提(ti)供(gong)(gong)。
(1)公共建筑加熱(re)設(she)備(bei)的(de)選擇:加熱(re)設(she)備(bei)是熱(re)水供應系統的(de)核心,對于熱(re)源充(chong)足的(de)地區采(cai)用半即熱(re)式汽(qi)水熱(re)交換器,它具有體積小,占地小,自(zi)控精確,浮(fu)動(dong)盤(pan)管,自(zi)動(dong)除(chu)垢(gou),自(zi)動(dong)過冷(leng),熱(re)水出水快,防“軍團(tuan)菌(jun)”產生等優點(dian)。
(2)熱水(shui)系統的BA設計:熱水系統(tong)的BA設計(ji)主(zhu)要(yao)是通過(guo)壓力、溫度信號實現對熱交換器、熱水(shui)循環泵的啟(qi)停、故障,熱水(shui)溫度的監視(shi)控制。
2.3給水支管的布置與敷設
給(gei)水(shui)供應(ying)系(xi)統沒有(you)固定的(de)形式,設計時應(ying)根據用(yong)戶(hu)的(de)要求,結合(he)室外給(gei)水(shui)系(xi)統的(de)實際情況經技術(shu)經濟比較或(huo)采用(yong)綜合(he)評判法確定供水(shui)方式。普通住(zhu)宅給(gei)水(shui)系(xi)統我們應(ying)本著節能、便于(yu)管(guan)理(li)的(de)原(yuan)則來選用(yong)設計方案。當(dang)一戶(hu)設有(you)兩(liang)個或(huo)兩(liang)個以上衛生間,給(gei)水(shui)管(guan)道需穿越房間時,橫管(guan)最(zui)好(hao)設于(yu)樓(lou)板墊層中,樓(lou)板降低7cm―l0cm,墊層采(cai)用(yong)渣或細(xi)石混凝土(tu)。當有采(cai)暖(nuan)管道穿梁(liang)敷設(或貼樓板下安裝),給水橫管應與采暖管道并排安裝,管道應盡量布置于客廳、餐廳等部位,這些位置是住戶裝修的重點區域,便于住戶在裝修中合理方便的處理管道。給水支管宜敷設在樓(地)面的找(zhao)平層(ceng)或沿墻敷(fu)設(she)在管槽(cao)內,敷(fu)設(she)在找(zhao)平層(ceng)或管槽(cao)內的給(gei)水支管外(wai)徑(jing)不宜大于25mm。實際上,如果將接往兩(liang)個或兩(liang)個以上用水點給水支管串聯在一起,其支管外徑(jing)均會超過25mm。因(yin)此,為(wei)了滿足規(gui)范要求,給水(shui)支管人戶后(hou)(hou)即接入分水(shui)器,分水(shui)器暗(an)設于(yu)廚房或衛(wei)生間墻體內,通過分水(shui)器后(hou)(hou)接往(wang)各用水(shui)點,其支管外(wai)徑均可控制在25mm以(yi)下。
三、排水設計
3.1廚房排水管道的設置
廚(chu)房洗(xi)滌池(chi)排(pai)水(shui)支管(guan)可(ke)直接在樓板上(shang)接人排(pai)水(shui)立(li)管(guan)。而(er)對于廚(chu)房是否(fou)設(she)地漏(lou)(lou),目前還存(cun)在較大爭(zheng)議,建議廚(chu)房內(nei)不設(she)地漏(lou)(lou):現代生(sheng)活中(zhong)廚(chu)房地面一般已很少用水(shui)沖(chong)洗(xi),少量(liang)的(de)濺水(shui)用抹布就可(ke)完(wan)成地面的(de)清潔,廚(chu)房地漏(lou)(lou)由于長(chang)時間(jian)無水(shui)補充,水(shui)封內(nei)存(cun)水(shui)蒸(zheng)發后臭氣反(fan)由地漏(lou)(lou)進(jin)入室內(nei)。同時,取消地漏(lou)(lou)還可(ke)避免地漏(lou)(lou)排(pai)水(shui)支管(guan)進(jin)入下(xia)層戶(hu)內(nei)空間(jian)。
3.2衛生間排水管道的設置
新設計的(de)住宅應致力(li)于取消伸入下層住戶空間(jian)的(de)排水橫管,具體(ti)做法有:
(1)使(shi)衛生間地板面(mian)下沉,管道敷(fu)設(she)在填渣層中。
(2)使(shi)衛生(sheng)間(jian)地板面不下沉,而(er)使(shi)用P形坐便器(后出口式),使(shi)得下水(shui)管(guan)(guan)在本層與立管(guan)(guan)銜接。地(di)漏采(cai)用側壁式,洗(xi)臉盆、浴缸等排水(shui)管(guan)(guan)也在地(di)面以(yi)上(shang)敷設與立管(guan)(guan)銜接。這兩種做(zuo)法均可以(yi)使(shi)下水(shui)管(guan)(guan)道(dao)每層水(shui)平分隔開,若需要檢修可以(yi)獨(du)戶進行,不影響鄰居。
(3)地漏與存(cun)水彎的(de)配合問(wen)題,傳統鐘(zhong)罩式地漏的(de)水封容易揮發,常常造成下水道異味和排(pai)水口溢出的(de)液體(ti)進入室內,形成室內污染。所以在(zai)給排(pai)水設計(ji)中,必須(xu)重視這個問(wen)題。
3.3污水系統
室內一般糞便污水(shui)(shui)和其他(ta)廢水(shui)(shui)合流,高層建筑的生(sheng)活污水(shui)(shui)立(li)管設置(zhi)專(zhuan)用通氣立(li)管,糞便污水(shui)(shui)經室外化(hua)糞池(chi)處理后(hou)排(pai)(pai)入市(shi)政(zheng)排(pai)(pai)水(shui)(shui)管網,職工食堂(tang)和營業的含油污水(shui)(shui)單獨設隔油處理。為(wei)改(gai)善底層排(pai)(pai)水(shui)(shui)條件,采(cai)用底層污水(shui)(shui)獨立(li)出戶,地下室污水(shui)(shui)設污水(shui)(shui)集(ji)水(shui)(shui)坑(keng)及潛污泵,經提升后(hou)排(pai)(pai)至(zhi)室外。為(wei)減少投資,方便管理,除規模很(hen)大的建筑群或有(you)關部門提出明確的要(yao)求需要(yao)做中水(shui)(shui)設計外,一般小規模的中水(shui)(shui)系(xi)統,由于(yu)管理等問題,運(yun)行(xing)情況都不太好。
3.4給排水管道的設計
給排水立管應盡量置于同一個位置,最好位于通風道附近,以便于住戶進行裝修包裹。在有條件時最好設置管道井,可以將水表設于其中以做到水表出戶。當一戶設有兩個或兩個以上衛生間,給水管道需要穿越房間時,橫管(管(guan)徑小于De25)最好(hao)設(she)于(yu)樓板(ban)面找平層(ceng)中。
四、結語
室內給(gei)排(pai)水系(xi)統(tong)看似簡(jian)單,但(dan)它與(yu)居民的(de)日常生活息(xi)息(xi)相關。作為給(gei)排(pai)水設(she)計人員(yuan),應本(ben)著技(ji)術、安全、美觀、實用、經(jing)濟的(de)原則,在實踐中(zhong)努力創新,尋求最佳的(de)給(gei)排(pai)水設(she)計方案,適應住宅設(she)計發(fa)展的(de)新要求,滿(man)足人民群眾不斷(duan)提高(gao)的(de)物質(zhi)文(wen)化和(he)生活要求。
推薦閱讀:
【室內物理環境設計】房間隔音不好怎么辦 房間隔音裝修方法大全
【室內物理環境設計】家居保溫隔熱設計方案 6招教裝出節能保溫房