【室內物理環境設(she)計(ji)】家居給排水系統設(she)計(ji) 家居出水入水有道
一、室內給排水概述
1.1室內給水
從建筑物(wu)(wu)內部結(jie)構(gou)來說,給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)包括生活給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、生產給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、中水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、消防給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)、以及組(zu)合給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)。例如(ru)自(zi)(zi)動排(pai)氣(qi)(qi)閥就是屬(shu)于給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)。設有延時(shi)(shi)(shi)(shi)自(zi)(zi)閉(bi)閥的(de)(de)(de)(de)蹲式大便器的(de)(de)(de)(de)室內給(gei)水(shui)(shui)(shui)(shui)(shui)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong),如(ru)學校、旅館、辦公樓(lou)等(deng),如(ru)果在給(gei)水(shui)(shui)(shui)(shui)(shui)管(guan)系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)的(de)(de)(de)(de)最頂層設有自(zi)(zi)閉(bi)閥,最好在管(guan)系(xi)(xi)(xi)(xi)(xi)的(de)(de)(de)(de)最高(gao)點增(zeng)設自(zi)(zi)動排(pai)氣(qi)(qi)裝置。因為給(gei)水(shui)(shui)(shui)(shui)(shui)用的(de)(de)(de)(de)延時(shi)(shi)(shi)(shi)自(zi)(zi)閉(bi)閥能(neng)很(hen)好地(di)控(kong)制水(shui)(shui)(shui)(shui)(shui)流,但卻不能(neng)很(hen)好地(di)控(kong)制氣(qi)(qi)流。當系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)停(ting)水(shui)(shui)(shui)(shui)(shui)時(shi)(shi)(shi)(shi),給(gei)水(shui)(shui)(shui)(shui)(shui)管(guan)內常積存有大量的(de)(de)(de)(de)空氣(qi)(qi)。系(xi)(xi)(xi)(xi)(xi)統(tong)(tong)(tong)恢(hui)復供水(shui)(shui)(shui)(shui)(shui)后,管(guan)系(xi)(xi)(xi)(xi)(xi)內空氣(qi)(qi)常會被(bei)水(shui)(shui)(shui)(shui)(shui)流壓縮(suo)(suo)(suo)至管(guan)系(xi)(xi)(xi)(xi)(xi)頂部而形成一個壓縮(suo)(suo)(suo)空氣(qi)(qi)區。此時(shi)(shi)(shi)(shi)有人再按(an)下(xia)延時(shi)(shi)(shi)(shi)自(zi)(zi)閉(bi)閥的(de)(de)(de)(de)按(an)扭(niu)時(shi)(shi)(shi)(shi),則壓縮(suo)(suo)(suo)的(de)(de)(de)(de)空氣(qi)(qi)會伴隨著水(shui)(shui)(shui)(shui)(shui)流噴薄而出,常會將便器內的(de)(de)(de)(de)污(wu)物(wu)(wu)吹到地(di)面以上,甚至濺到入廁者的(de)(de)(de)(de)衣(yi)物(wu)(wu)上。在管(guan)系(xi)(xi)(xi)(xi)(xi)的(de)(de)(de)(de)最高(gao)點設一個自(zi)(zi)動排(pai)氣(qi)(qi)閥則可有效(xiao)地(di)解決這(zhe)一問(wen)題。
2.2室內排水
排(pai)(pai)(pai)水(shui)(shui)系(xi)統(tong)(tong)包(bao)括生活(huo)排(pai)(pai)(pai)水(shui)(shui)系(xi)統(tong)(tong),工業廢水(shui)(shui)排(pai)(pai)(pai)水(shui)(shui)系(xi)統(tong)(tong),以及屋(wu)面雨(yu)水(shui)(shui)排(pai)(pai)(pai)水(shui)(shui)系(xi)統(tong)(tong)。這些(xie)系(xi)統(tong)(tong)中包(bao)括了水(shui)(shui)質(zhi)處理,水(shui)(shui)質(zhi)、水(shui)(shui)溫、水(shui)(shui)壓保(bao)證及供水(shui)(shui)、配水(shui)(shui)、排(pai)(pai)(pai)水(shui)(shui)、通氣等眾多(duo)技術內涵。隨著(zhu)(zhu)社(she)會的(de)(de)(de)進步和科(ke)學得(de)到(dao)發展(zhan),室內給排(pai)(pai)(pai)水(shui)(shui)在(zai)(zai)不斷派生出各(ge)種新(xin)(xin)(xin)的(de)(de)(de)子系(xi)統(tong)(tong),新(xin)(xin)(xin)技術、新(xin)(xin)(xin)材料日新(xin)(xin)(xin)月異地涌現(xian)。室內給排(pai)(pai)(pai)水(shui)(shui)已(yi)成為(wei)我國(guo)現(xian)代化建設中一支(zhi)不可忽視(shi)的(de)(de)(de)力量,在(zai)(zai)生活(huo)中起著(zhu)(zhu)舉足輕(qing)重的(de)(de)(de)作(zuo)用。對(dui)于廚(chu)房和廁(ce)所(suo)相(xiang)鄰的(de)(de)(de)住宅來說,如果廚(chu)、廁(ce)是單獨(du)的(de)(de)(de)排(pai)(pai)(pai)水(shui)(shui)管系(xi)統(tong)(tong),則(ze)在(zai)(zai)最底層為(wei)兩系(xi)統(tong)(tong)作(zuo)一個緊急排(pai)(pai)(pai)出聯通。從對(dui)目前我國(guo)居民的(de)(de)(de)生活(huo)習慣來說,下水(shui)(shui)管道(dao)發生堵塞現(xian)象發生的(de)(de)(de)可能性非常(chang)大(da),也可以說只是堵的(de)(de)(de)次數多(duo)與少的(de)(de)(de)問(wen)題。如果室內設計人員對(dui)傳統(tong)(tong)作(zuo)法稍做改動,則(ze)可在(zai)(zai)很大(da)程度上方便用戶。
二、室內給水設計
2.1生活給水系統
建(jian)筑物內(nei)應盡量利用室外管網的水(shui)(shui)壓(ya)直接供水(shui)(shui),當水(shui)(shui)壓(ya)不(bu)滿足要(yao)求時設(she)加壓(ya)裝置,生活水(shui)(shui)池及其泵房設(she)在(zai)底(di)層,屋頂設(she)水(shui)(shui)箱,各(ge)配水(shui)(shui)點處的靜水(shui)(shui)壓(ya)不(bu)宜大于0.45MPa,同時最(zui)高層水壓(ya)不(bu)宜小于0.10MPa,水壓大于0.35MPa的人戶管(guan)(guan),應設減壓(ya)設施,且為了利用(yong)外管(guan)(guan)網的水(shui)壓(ya),以(yi)節省能(neng)耗,一般(ban)以(yi)外管(guan)(guan)網能(neng)滿(man)足(zu)水(shui)壓(ya)要求的樓層(ceng)為低(di)(di)壓(ya)區,空調冷卻塔的補水(shui)量一般(ban)均較(jiao)生(sheng)活用(yong)水(shui)量大得多(duo),因(yin)此有條件(jian)的宜將冷卻塔置(zhi)于低(di)(di)壓(ya)區。市政壓(ya)力不能(neng)滿(man)足(zu)要求的給水(shui)系統的BA設(she)計小區每棟單體均(jun)設(she)有水(shui)(shui)池、水(shui)(shui)箱、水(shui)(shui)泵,由于數量多(duo)(duo),如用傳統的管理(li)方(fang)式務必(bi)造成(cheng)人力、資源(yuan)的浪(lang)費,給管理(li)帶來很多(duo)(duo)不便,一般(ban)設(she)計中采用BA系統(tong)對各(ge)個水池、水箱(xiang)、水泵的運行狀態(tai)、故障狀態(tai)等進行監視、控制。BA系(xi)統中的(de)(de)自(zi)動抄表(biao)系(xi)統解決了人工抄表(biao)帶來(lai)的(de)(de)諸(zhu)多不便,更好地為住戶服務。給水系(xi)統的(de)(de)BA設計主要是通(tong)過液位、壓力、流量(liang)等訊號對加壓泵、水池、水箱運行狀態(tai)進(jin)行監視、控制(zhi)。
2.2熱水系統
住宅樓熱(re)水(shui)(shui)由各自煤氣、太陽能、電熱(re)水(shui)(shui)器提(ti)供(gong),公(gong)共(gong)建筑熱(re)水(shui)(shui)由集中熱(re)水(shui)(shui)供(gong)應系統提(ti)供(gong)。
(1)公(gong)共建筑加熱設(she)備(bei)的選擇:加熱設(she)備(bei)是熱水(shui)供應(ying)系統(tong)的核心,對于熱源充(chong)足的地(di)區(qu)采用半即(ji)熱式汽水(shui)熱交換(huan)器,它具有體積小(xiao),占地(di)小(xiao),自(zi)控精確,浮動盤管,自(zi)動除垢,自(zi)動過冷,熱水(shui)出水(shui)快,防“軍團菌(jun)”產生等(deng)優點。
(2)熱水系統的BA設計:熱水系統(tong)的BA設計(ji)主要是通(tong)過壓力(li)、溫度信號實現對(dui)熱交換器、熱水循(xun)環泵的啟停、故障,熱水溫度的監視控(kong)制(zhi)。
2.3給水支管的布置與敷設
給(gei)水(shui)供(gong)應(ying)系統沒有固定(ding)的形式(shi),設(she)計時(shi)應(ying)根(gen)據(ju)用(yong)(yong)戶的要(yao)求,結合室外給(gei)水(shui)系統的實(shi)際(ji)情(qing)況經技術經濟比較或采用(yong)(yong)綜合評判(pan)法確定(ding)供(gong)水(shui)方式(shi)。普通(tong)住宅給(gei)水(shui)系統我們(men)應(ying)本著節(jie)能、便于管(guan)理的原則(ze)來選(xuan)用(yong)(yong)設(she)計方案。當一(yi)戶設(she)有兩個或兩個以上(shang)衛生(sheng)間,給(gei)水(shui)管(guan)道需穿越房間時(shi),橫管(guan)最好設(she)于樓(lou)(lou)板(ban)墊層中,樓(lou)(lou)板(ban)降(jiang)低7cm―l0cm,墊(dian)層采用(yong)渣或(huo)細(xi)石混凝土。當(dang)有采暖管(guan)道穿梁敷設(或貼樓板下安裝),給水橫管應與采暖管道并排安裝,管道應盡量布置于客廳、餐廳等部位,這些位置是住戶裝修的重點區域,便于住戶在裝修中合理方便的處理管道。給水支管宜敷設在樓(地)面的找平(ping)層或(huo)沿墻敷設在(zai)管(guan)槽內,敷設在(zai)找平(ping)層或(huo)管(guan)槽內的給水支(zhi)管(guan)外徑不宜大(da)于25mm。實際(ji)上,如果將接往兩(liang)(liang)個或兩(liang)(liang)個以上用水(shui)點給水(shui)支(zhi)管串聯(lian)在一起,其支(zhi)管外徑均會超過(guo)25mm。因此,為(wei)了滿足(zu)規(gui)范要求(qiu),給水(shui)(shui)(shui)支管人戶后(hou)即接(jie)入分(fen)水(shui)(shui)(shui)器,分(fen)水(shui)(shui)(shui)器暗(an)設于(yu)廚房或衛(wei)生間(jian)墻體(ti)內,通過(guo)分(fen)水(shui)(shui)(shui)器后(hou)接(jie)往各用水(shui)(shui)(shui)點,其支管外徑均(jun)可控制在25mm以下。
三、排水設計
3.1廚房排水管道的設置
廚(chu)(chu)房(fang)洗(xi)滌池排(pai)水(shui)支(zhi)管(guan)可直接在樓板上接人(ren)排(pai)水(shui)立管(guan)。而對于廚(chu)(chu)房(fang)是否設地(di)漏(lou),目前還(huan)存在較大爭議(yi),建(jian)議(yi)廚(chu)(chu)房(fang)內不設地(di)漏(lou):現代生活中(zhong)廚(chu)(chu)房(fang)地(di)面(mian)一般(ban)已(yi)很少(shao)用水(shui)沖洗(xi),少(shao)量的(de)濺水(shui)用抹布(bu)就可完成地(di)面(mian)的(de)清(qing)潔,廚(chu)(chu)房(fang)地(di)漏(lou)由(you)于長時間無水(shui)補充(chong),水(shui)封內存水(shui)蒸發后(hou)臭氣反由(you)地(di)漏(lou)進入室內。同(tong)時,取消地(di)漏(lou)還(huan)可避免地(di)漏(lou)排(pai)水(shui)支(zhi)管(guan)進入下層戶(hu)內空間。
3.2衛生間排水管道的設置
新設(she)計的(de)住宅應致力于取消(xiao)伸入下(xia)層住戶空間的(de)排水橫管,具體做法(fa)有:
(1)使衛生(sheng)間地板(ban)面下沉,管道敷設在填渣層中。
(2)使衛生間(jian)地(di)板(ban)面(mian)不(bu)下(xia)沉,而使用P形坐便器(后出(chu)口式),使(shi)得(de)下水管在本層(ceng)與(yu)(yu)立(li)管銜(xian)接。地漏采用側(ce)壁式,洗臉(lian)盆、浴缸等排水管也(ye)在地面(mian)以上敷(fu)設與(yu)(yu)立(li)管銜(xian)接。這兩種(zhong)做法均(jun)可以使(shi)下水管道每層(ceng)水平(ping)分隔開,若(ruo)需(xu)要檢修可以獨戶進行,不影(ying)響鄰居。
(3)地(di)漏(lou)與存水(shui)彎的(de)配(pei)合(he)問題,傳統鐘罩(zhao)式(shi)地(di)漏(lou)的(de)水(shui)封容易揮發,常常造成下水(shui)道異(yi)味和排(pai)(pai)水(shui)口溢出的(de)液體進(jin)入室(shi)內,形成室(shi)內污(wu)染。所以在給排(pai)(pai)水(shui)設計中,必須(xu)重視這個問題。
3.3污水系統
室內一般糞便污(wu)水(shui)(shui)和其他廢水(shui)(shui)合流,高層(ceng)建(jian)筑(zhu)的(de)生活(huo)污(wu)水(shui)(shui)立管設(she)(she)置專用通氣立管,糞便污(wu)水(shui)(shui)經室外化糞池處理(li)(li)后(hou)排(pai)入市(shi)政排(pai)水(shui)(shui)管網,職工食堂和營業的(de)含油(you)污(wu)水(shui)(shui)單獨(du)設(she)(she)隔油(you)處理(li)(li)。為改善底層(ceng)排(pai)水(shui)(shui)條件,采用底層(ceng)污(wu)水(shui)(shui)獨(du)立出戶,地下室污(wu)水(shui)(shui)設(she)(she)污(wu)水(shui)(shui)集水(shui)(shui)坑(keng)及潛(qian)污(wu)泵,經提(ti)升后(hou)排(pai)至室外。為減少(shao)投資,方便管理(li)(li),除規模(mo)很大的(de)建(jian)筑(zhu)群或有關部門提(ti)出明確(que)的(de)要求需要做(zuo)中水(shui)(shui)設(she)(she)計外,一般小規模(mo)的(de)中水(shui)(shui)系(xi)統,由于(yu)管理(li)(li)等問題,運行情(qing)況都不太(tai)好。
3.4給排水管道的設計
給排水立管應盡量置于同一個位置,最好位于通風道附近,以便于住戶進行裝修包裹。在有條件時最好設置管道井,可以將水表設于其中以做到水表出戶。當一戶設有兩個或兩個以上衛生間,給水管道需要穿越房間時,橫管(管徑小(xiao)于De25)最(zui)好(hao)設于樓板面找平層中。
四、結語
室內給(gei)排水(shui)系(xi)統看(kan)似簡(jian)單,但它與居民(min)的日常生活(huo)息息相關。作為給(gei)排水(shui)設(she)計人員,應(ying)本著技術、安全(quan)、美(mei)觀、實(shi)用、經濟的原則(ze),在實(shi)踐中努力(li)創新(xin)(xin),尋求最佳的給(gei)排水(shui)設(she)計方案,適應(ying)住(zhu)宅設(she)計發展的新(xin)(xin)要(yao)求,滿足人民(min)群眾不斷提高的物質文化和生活(huo)要(yao)求。
推薦閱讀:
【室內物理環境設計】房間隔音不好怎么辦 房間隔音裝修方法大全
【室內物理環境設計】家居保溫隔熱設計方案 6招教裝出節能保溫房
【室內物理環境設(she)計(ji)】家居電氣設(she)計(ji) 家庭裝修電氣(qi)設計(ji)經驗提前看(kan)