隱框玻璃幕墻施工工藝
一、工藝流程
施(shi)工準備(bei)→測量(liang)放線→預(yu)埋(mai)件安(an)(an)裝處理(li)→連接角(jiao)碼(ma)安(an)(an)裝→立柱安(an)(an)裝→橫梁安(an)(an)裝→結構玻璃裝配組件制(zhi)作安(an)(an)裝→耐候硅酮密封膠嵌縫→清潔檢查(cha)→竣工驗(yan)收(shou)
二、施工工藝及施工要點:
A、施(shi)工準(zhun)備(bei):材料準(zhun)備(bei):根據圖紙(zhi)及(ji)工程情況,編(bian)制詳(xiang)細的(de)材料訂貨供(gong)應(ying)計劃單。施(shi)工機具:對(dui)所用(yong)(yong)機具進行檢測,確保其性能良好。人(ren)員準(zhun)備(bei):對(dui)技(ji)術(shu)工人(ren)進行技(ji)術(shu)培訓、交底。技(ji)術(shu)準(zhun)備(bei):熟悉圖紙(zhi),準(zhun)備(bei)有關圖集、質量驗收標準(zhun)和內業(ye)資(zi)料所用(yong)(yong)的(de)表格。
B、測(ce)量(liang)放(fang)線(xian)(xian):根(gen)(gen)據土建(jian)(jian)(jian)(jian)單位(wei)提供(gong)的中心線(xian)(xian)及標(biao)高(gao)點進,以(yi)建(jian)(jian)(jian)(jian)筑物的軸(zhou)(zhou)線(xian)(xian)為(wei)依據,對(dui)巳完工的土建(jian)(jian)(jian)(jian)結(jie)構進行測(ce)量(liang)。根(gen)(gen)據土建(jian)(jian)(jian)(jian)標(biao)高(gao)基準線(xian)(xian)測(ce)預(yu)埋件標(biao)高(gao)中心線(xian)(xian),檢(jian)查預(yu)埋件標(biao)高(gao)偏(pian)(pian)差;找出幕(mu)墻(qiang)(qiang)立(li)(li)(li)(li)柱與建(jian)(jian)(jian)(jian)筑軸(zhou)(zhou)線(xian)(xian)的關(guan)(guan)系,根(gen)(gen)據土建(jian)(jian)(jian)(jian)軸(zhou)(zhou)線(xian)(xian)測(ce)量(liang)立(li)(li)(li)(li)柱軸(zhou)(zhou)線(xian)(xian),檢(jian)查預(yu)埋件左(zuo)右(you)偏(pian)(pian)差。整理(li)以(yi)上測(ce)量(liang)結(jie)果,確定(ding)(ding)(ding)(ding)幕(mu)墻(qiang)(qiang)立(li)(li)(li)(li)柱分隔的調整處(chu)理(li)方(fang)案。根(gen)(gen)據設(she)計圖紙和土建(jian)(jian)(jian)(jian)結(jie)構誤差確定(ding)(ding)(ding)(ding)幕(mu)墻(qiang)(qiang)立(li)(li)(li)(li)柱外平面(mian)軸(zhou)(zhou)線(xian)(xian)距(ju)建(jian)(jian)(jian)(jian)筑物外平面(mian)軸(zhou)(zhou)線(xian)(xian)的距(ju)離,在(zai)(zai)墻(qiang)(qiang)面(mian)頂(ding)部合適位(wei)置用鋼琴(qin)線(xian)(xian)定(ding)(ding)(ding)(ding)出幕(mu)墻(qiang)(qiang)立(li)(li)(li)(li)柱外平面(mian)軸(zhou)(zhou)線(xian)(xian)。用鋼琴(qin)線(xian)(xian)定(ding)(ding)(ding)(ding)出每(mei)條立(li)(li)(li)(li)柱的左(zuo)右(you)位(wei)置。每(mei)一定(ding)(ding)(ding)(ding)位(wei)軸(zhou)(zhou)線(xian)(xian)間(jian)的誤差在(zai)(zai)本(ben)定(ding)(ding)(ding)(ding)位(wei)軸(zhou)(zhou)線(xian)(xian)間(jian)消化,誤差在(zai)(zai)每(mei)個分格間(jian)分攤(tan)小于(yu)2mm。確定(ding)(ding)(ding)(ding)立(li)(li)(li)(li)柱頂(ding)標(biao)高(gao)與樓層標(biao)高(gao)的關(guan)(guan)系,沿樓板外沿彈出墨線(xian)(xian)定(ding)(ding)(ding)(ding)出立(li)(li)(li)(li)柱頂(ding)標(biao)高(gao)線(xian)(xian)。測(ce)量(liang)工具:經緯儀(yi)、水準儀(yi)(有時(shi)也用水平管)和線(xian)(xian)墜。
C、預埋(mai)件(jian)安裝處理:定位預埋(mai)件(jian)安裝位置,打鉆安裝。要求預埋(mai)件(jian)位置準確、埋(mai)設(she)牢(lao)固。標高偏差不大于9mm,左右位移不大于20mm。
D、連接(jie)角碼(ma)(ma)安(an)裝:連接(jie)角碼(ma)(ma)焊(han)接(jie)鋼板(ban)。連接(jie)角碼(ma)(ma)端部在焊(han)接(jie)鋼板(ban)外無法(fa)時,切短角碼(ma)(ma),增加(jia)焊(han)縫長度;角碼(ma)(ma)側(ce)邊無法(fa)焊(han)接(jie)時,切去(qu)角碼(ma)(ma)邊緣(yuan),留出焊(han)縫;預埋板(ban)兩個(ge)方向偏差很大(da)時,補(bu)鋼板(ban);預埋板(ban)凹入或(huo)傾斜過大(da)時,補(bu)加(jia)墊(dian)板(ban)。
F、立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang):先(xian)把(ba)芯套(tao)(接(jie)長立(li)(li)柱(zhu)與立(li)(li)柱(zhu)用(yong),上(shang)(shang)下(xia)(xia)層立(li)(li)柱(zhu)之間留20mm以(yi)上(shang)(shang)的(de)(de)(de)伸人縫。)插入(ru)立(li)(li)柱(zhu)內,然(ran)后(hou)在(zai)立(li)(li)柱(zhu)上(shang)(shang)鉆孔,將連(lian)接(jie)角碼用(yong)不(bu)(bu)銹鋼(gang)螺(luo)栓(shuan)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)在(zai)立(li)(li)柱(zhu)上(shang)(shang),二者之間用(yong)防腐墊片(pian)隔(ge)開。立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)順序由下(xia)(xia)至上(shang)(shang)。使立(li)(li)柱(zhu)上(shang)(shang)巳有的(de)(de)(de)中心線和(he)測量(liang)時所定的(de)(de)(de)立(li)(li)柱(zhu)站線(鋼(gang)琴線)重合,立(li)(li)柱(zhu)頂和(he)測量(liang)時所定的(de)(de)(de)標(biao)高控制線水平,另一(yi)焊(han)(han)(han)(han)工把(ba)連(lian)接(jie)角碼臨時點焊(han)(han)(han)(han)在(zai)預埋鋼(gang)板上(shang)(shang),然(ran)后(hou)調整立(li)(li)柱(zhu)位(wei)置。第一(yi)條立(li)(li)柱(zhu)準(zhun)(zhun)確無誤后(hou),把(ba)上(shang)(shang)一(yi)層立(li)(li)柱(zhu)套(tao)入(ru)下(xia)(xia)一(yi)層立(li)(li)柱(zhu)芯套(tao),就(jiu)位(wei)準(zhun)(zhun)確后(hou)點焊(han)(han)(han)(han)。如此循環(huan),完成一(yi)組立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)。一(yi)面幕墻(qiang)立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)完畢,經(jing)檢查位(wei)置準(zhun)(zhun)確、安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)牢固后(hou),再按焊(han)(han)(han)(han)縫要(yao)求(qiu)加(jia)焊(han)(han)(han)(han)。立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)標(biao)高偏(pian)差(cha)不(bu)(bu)應(ying)大(da)于(yu)3mm,軸線前后(hou)偏(pian)差(cha)不(bu)(bu)應(ying)大(da)于(yu)2mm,左右偏(pian)差(cha)應(ying)大(da)于(yu)3mm;相(xiang)鄰兩根立(li)(li)柱(zhu)安(an)(an)(an)(an)裝(zhuang)(zhuang)(zhuang)標(biao)高偏(pian)差(cha)不(bu)(bu)應(ying)大(da)于(yu)3mm,立(li)(li)柱(zhu)的(de)(de)(de)最大(da)標(biao)高偏(pian)差(cha)不(bu)(bu)應(ying)大(da)于(yu)5mm;相(xiang)鄰兩根立(li)(li)柱(zhu)的(de)(de)(de)距離偏(pian)差(cha)不(bu)(bu)應(ying)大(da)于(yu)2mm。
E、橫梁制作安(an)(an)裝(zhuang):用水準儀把樓層標高線(xian)引到立柱(zhu)上。以樓層標高線(xian)為(wei)基準,在(zai)立柱(zhu)側面標出橫梁位置。將橫梁兩(liang)端的(de)連(lian)接件(鋁角碼)和彈性橡膠墊(dian)安(an)(an)裝(zhuang)在(zai)立柱(zhu)的(de)預定位置,要求安(an)(an)裝(zhuang)牢(lao)固、接縫嚴密。橫梁的(de)安(an)(an)裝(zhuang)應由下(xia)向上進(jin)行,當安(an)(an)裝(zhuang)完成時,應進(jin)行檢(jian)查、調整、校正、固定,使其符合質量要求。相(xiang)鄰兩(liang)根橫梁的(de)水平標高偏(pian)差不(bu)(bu)(bu)應大于(yu)(yu)1mm。標高偏(pian)差:當一(yi)幅寬度小于(yu)(yu)或等于(yu)(yu)35m時,不(bu)(bu)(bu)應大于(yu)(yu)5mm;當一(yi)幅寬度大于(yu)(yu)35m時,不(bu)(bu)(bu)應大于(yu)(yu)7mm。
G、結構(gou)玻(bo)璃裝配(pei)組件制(zhi)作安裝:確定玻(bo)璃板(ban)塊(kuai)在(zai)(zai)立面上(shang)的水平(ping)、垂直位置,并在(zai)(zai)主框(kuang)格上(shang)劃線。玻(bo)璃板(ban)塊(kuai)臨時固(gu)定后(hou)對板(ban)塊(kuai)進行調(diao)整,調(diao)整標準橫平(ping)、豎直、面平(ping)。用壓塊(kuai)把玻(bo)璃板(ban)塊(kuai)固(gu)定在(zai)(zai)主框(kuang)格上(shang)。壓塊(kuai)間距不大于300mm。上(shang)壓塊(kuai)時要注意鉆孔,螺(luo)栓(shuan)采用M5×20不銹鋼機械螺(luo)栓(shuan)。壓塊(kuai)一定要壓緊。
H、耐(nai)候硅(gui)酮密封膠(jiao)嵌縫(feng):充分(fen)清(qing)潔板材間縫(feng)隙,不應有(you)水、油(you)漬、涂(tu)料(liao)、鐵銹、水泥砂(sha)漿(jiang)、灰塵(chen)(chen)等。充分(fen)清(qing)潔粘結面,加以(yi)干(gan)燥(zao)。為(wei)調整縫(feng)的(de)深度,避免三邊(bian)粘膠(jiao),縫(feng)內填泡沫(mo)塑料(liao)棒(bang)。在縫(feng)兩(liang)側貼保護(hu)膠(jiao)紙保護(hu)玻璃(li)不被污染(ran)。注(zhu)膠(jiao)后將膠(jiao)縫(feng)表面抹平(ping),去(qu)掉多余的(de)膠(jiao)。注(zhu)膠(jiao)完畢,將保護(hu)紙撕掉,必要(yao)時用(yong)溶劑擦拭玻璃(li)。、膠(jiao)在未完全硬化前(qian),不要(yao)沾染(ran)灰塵(chen)(chen)和(he)劃(hua)傷。
I、保(bao)護(hu)和(he)清(qing)洗:保(bao)護(hu)和(he)清(qing)洗
J、竣(jun)(jun)工驗(yan)收:竣(jun)(jun)工驗(yan)收。
三、質量控制
1、質(zhi)量標準:請參照《玻璃(li)(li)幕墻工程技(ji)術規范》(JGJ102—96)和《玻璃(li)(li)幕墻工程質(zhi)量檢驗標準》(JGJ/T139—20016)。
2、質量管理要(yao)點:
材料控制:幕墻所使用的各種材(cai)料必(bi)須符合(he)設計和(he)規(gui)范(fan)要(yao)求。材(cai)料采(cai)購(gou)前必(bi)須弄清楚規(gui)范(fan)中(zhong)對該種材(cai)料有(you)何(he)質量(liang)要(yao)求。
各(ge)種構(gou)件在運輸(shu)過程中必須有可(ke)靠(kao)的保(bao)護措施。
立(li)柱放(fang)(fang)線(xian):立(li)柱放(fang)(fang)線(xian)是幕墻施(shi)工中(zhong)比(bi)較繁瑣的工序,立(li)柱放(fang)(fang)線(xian)是否準(zhun)確將影響整過(guo)施(shi)工過(guo)程(cheng)。測量(liang)人(ren)員在(zai)工作中(zhong)必須反(fan)復校對(dui),確保(bao)放(fang)(fang)線(xian)精確。
立柱與主(zhu)體結構(gou)的(de)連接點施工(gong)中,必(bi)須用合格焊工(gong)。焊接、防銹(xiu)、安裝精度必(bi)須合格。
構件安裝過(guo)程中,技術員要勤吊勤靠,確(que)保各種(zhong)構件的(de)安裝精度(du)和(he)可靠度(du)符合要求。
幕墻轉角、上下邊緣(yuan)、沉降(jiang)縫(feng)部位的處理要(yao)美觀,防(fang)火、防(fang)水、防(fang)雷等要(yao)滿(man)足(zu)要(yao)求。
四、安全措施
1、安裝幕墻用(yong)的施工(gong)機(ji)具在使用(yong)前(qian)必(bi)須進(jin)行嚴格檢(jian)驗。手持(chi)電動工(gong)具用(yong)前(qian)作絕緣電壓試(shi)驗;手持(chi)玻璃吸(xi)盤(pan)和玻璃吸(xi)盤(pan)安裝機(ji),須作吸(xi)附(fu)重量和吸(xi)附(fu)持(chi)續時間試(shi)驗。
2、施工人(ren)員配備必要的勞動保(bao)護用(yong)品,防止(zhi)人(ren)員及物件(jian)墜落。
3、防止密封材料(liao)在工程使用中溶劑中毒(du),且(qie)要保管(guan)好溶劑,以防發生火(huo)災。
4、現場(chang)焊(han)接時(shi),應在焊(han)件下方加設(she)接火(huo)斗。
5、設專職安全員進行監督和巡回檢查。