冷水機組工作原理
制(zhi)(zhi)冷(leng)(leng)(leng)工質(zhi)(即制(zhi)(zhi)冷(leng)(leng)(leng)劑)在(zai)蒸(zheng)發(fa)器(qi)(qi)內吸(xi)收(shou)被(bei)冷(leng)(leng)(leng)卻物的熱(re)(re)量并汽(qi)化成蒸(zheng)汽(qi),壓(ya)縮(suo)(suo)機(ji)不斷地(di)將產(chan)生的蒸(zheng)汽(qi)從(cong)蒸(zheng)發(fa)器(qi)(qi)中抽出,并進(jin)行壓(ya)縮(suo)(suo),經(jing)壓(ya)縮(suo)(suo)后(hou)(hou)的高(gao)溫、高(gao)壓(ya)蒸(zheng)汽(qi)被(bei)送到冷(leng)(leng)(leng)凝器(qi)(qi)后(hou)(hou)向(xiang)冷(leng)(leng)(leng)卻介質(zhi)(如水、空氣等)放(fang)熱(re)(re)冷(leng)(leng)(leng)凝成高(gao)壓(ya)液體,在(zai)經(jing)節流(liu)機(ji)構降(jiang)壓(ya)后(hou)(hou)進(jin)入蒸(zheng)發(fa)器(qi)(qi),再次汽(qi)化,吸(xi)收(shou)被(bei)冷(leng)(leng)(leng)卻物體的熱(re)(re)量,如此周而復始地(di)循環。制(zhi)(zhi)熱(re)(re)時,制(zhi)(zhi)冷(leng)(leng)(leng)劑通過四通閥改變制(zhi)(zhi)冷(leng)(leng)(leng)劑流(liu)動方(fang)(fang)向(xiang),制(zhi)(zhi)冷(leng)(leng)(leng)劑流(liu)動方(fang)(fang)向(xiang)與制(zhi)(zhi)冷(leng)(leng)(leng)時剛好相反,制(zhi)(zhi)冷(leng)(leng)(leng)劑先經(jing)過蒸(zheng)發(fa)器(qi)(qi),再回(hui)到冷(leng)(leng)(leng)凝器(qi)(qi),最(zui)后(hou)(hou)回(hui)到壓(ya)縮(suo)(suo)機(ji)。
冷水空調的原理
冷水空(kong)(kong)調(diao)(diao)即(ji)蒸發式冷氣(qi)機,高效(xiao)冷水空(kong)(kong)調(diao)(diao)是(shi)依靠蒸發吸收空(kong)(kong)氣(qi)中的熱量達到(dao)降溫目的,根據自然物理現象“水蒸發效(xiao)率(lv)”這(zhe)一原理:當熱空(kong)(kong)氣(qi)經過實際換熱面積100倍有水蒸發的濕簾時,其大量的熱將被空(kong)(kong)氣(qi)吸收,從而實現空(kong)(kong)氣(qi)降溫的過程,它與傳統空(kong)(kong)調(diao)(diao)相比最大的特點是(shi)不用壓縮機,所以(yi)它節能、環保(bao)、并有新鮮、潔凈的空(kong)(kong)氣(qi),為(wei)您創造更加(jia)健康(kang),舒適的工(gong)作環境。
螺桿式冷水機組選型
1、螺桿式冷(leng)水機組的主要控制(zhi)(zhi)(zhi)參(can)數為制(zhi)(zhi)(zhi)冷(leng)性(xing)能系數,額(e)定(ding)制(zhi)(zhi)(zhi)冷(leng)量,輸(shu)入(ru)功率以及(ji)制(zhi)(zhi)(zhi)冷(leng)劑類型等。
2、螺桿式(shi)(shi)冷(leng)水(shui)機組的(de)選用(yong)應根據冷(leng)負荷(he)(he)及用(yong)途來(lai)考慮(lv)。對于(yu)低負荷(he)(he)運轉工況時(shi)間較長(chang)的(de)制(zhi)冷(leng)系(xi)統,宜選用(yong)多機頭活塞式(shi)(shi)壓縮機組或螺桿式(shi)(shi)壓縮機組,便于(yu)調節和節能。
3、選(xuan)用(yong)冷(leng)水(shui)(shui)機組時,優(you)(you)先考慮(lv)性能(neng)系數(shu)值(zhi)較(jiao)高的(de)機組。根(gen)據資料統計(ji),一般冷(leng)水(shui)(shui)機組全年在(zai)100%負荷(he)下(xia)運行時間(jian)(jian)約占總運行時間(jian)(jian)的(de)1/4以下(xia)。總運行時間(jian)(jian)內100%、75%、50%、25%負荷(he)的(de)運行時間(jian)(jian)比例(li)大致為2.3%、41.5%、46.1%、10.1%。因此,在(zai)選(xuan)用(yong)冷(leng)水(shui)(shui)機組時應優(you)(you)先考慮(lv)效率曲(qu)線比較(jiao)平坦的(de)機型。同時,在(zai)設計(ji)選(xuan)用(yong)時應考慮(lv)冷(leng)水(shui)(shui)機組負荷(he)的(de)調(diao)節范圍。多(duo)機頭螺(luo)桿式冷(leng)水(shui)(shui)機組部(bu)分負荷(he)性能(neng)優(you)(you)良,可根(gen)據實際情(qing)況(kuang)選(xuan)用(yong)。
4、選(xuan)用螺桿(gan)式(shi)冷(leng)水機組(zu)時,應(ying)注意名義工況的條件。螺桿(gan)式(shi)冷(leng)水機組(zu)的實際產冷(leng)量與下列因素有(you)關(guan):
a.冷水出水溫(wen)度(du)和流(liu)量;
b.冷(leng)卻水的進水溫度(du)、流量以及(ji)污垢(gou)系數(shu)。
5、選(xuan)用螺桿式冷水機組時,應注意(yi)該型號機組的(de)(de)正常工作范圍(wei),主要(yao)是主電(dian)機的(de)(de)電(dian)流限值是名義工況下的(de)(de)軸功率的(de)(de)電(dian)流值。
6、在設計選用中應(ying)注意:在名義工況流量下,冷水(shui)的(de)(de)出口溫(wen)度不(bu)應(ying)超(chao)過(guo)15℃,風冷機組(zu)室外干球溫(wen)度不(bu)應(ying)超(chao)過(guo)43℃。若必(bi)須超(chao)過(guo)上述范圍時,應(ying)了解壓縮機的(de)(de)使用范圍是否(fou)允(yun)許,所配主電機的(de)(de)功率是否(fou)足夠。