防火卷簾門安裝規范
1、安裝卷簾門的洞口上部不得設有(you)通風(feng)管(guan)、水管(guan)等;
2、電源線路(三相五(wu)線和(he)消(xiao)防中控信號線)由用(yong)戶鋪設到卷門機旁的電氣控制箱邊;
3、卷簾門安(an)裝好(hao)后,安(an)裝吊頂,吊頂邊緣應離簾(lian)板50MM,以(yi)免磨(mo)擦;
4、調試及使(shi)用時,嚴禁底部站人(ren)。電器(qi)設施不得擅自拆搬;
5、根據消(xiao)防管理(li)規定,防火卷簾門為(wei)消(xiao)防專用設(she)施,不得(de)改作(zuo)他(ta)用,卷簾正下方不得(de)堆放任何物品;
6、安裝調試(shi)后,每季度啟動一次(ci),以檢查(cha)電器、機(ji)械性能,檢查(cha)時注意操作安全(quan)。
防火簾卷門安裝注意事項
1、防火卷簾門電源
防火(huo)卷簾(lian)門(men)的供電(dian)電(dian)源應(ying)為消(xiao)防電(dian)源;供電(dian)和(he)控制(zhi)導線(xian)截面積、絕緣電(dian)阻(zu)、線(xian)路敷設和(he)保護管材質應(ying)符合規(gui)范要(yao)求。防火(huo)卷簾(lian)門(men)供電(dian)裝置的過電(dian)流保護整定值應(ying)符合設計要(yao)求。
2、防火卷簾門控制器
防火(huo)(huo)卷(juan)簾(lian)門(men)上(shang)(shang)面(mian)安(an)裝有(you)防火(huo)(huo)卷(juan)簾(lian)門(men)控(kong)(kong)制器控(kong)(kong)制防火(huo)(huo)卷(juan)簾(lian)門(men)進行上(shang)(shang)、下、停等動(dong)作。還(huan)要在兩側(ce)(人員無法(fa)操作側(ce)除外)分別設置手(shou)動(dong)按鈕控(kong)(kong)制電動(dong)防火(huo)(huo)卷(juan)簾(lian)門(men)的升(sheng)、降、停,并(bing)應在防火(huo)(huo)卷(juan)簾(lian)門(men)火(huo)(huo)災(zai)時(shi)下降關(guan)閉后提(ti)升(sheng)該防火(huo)(huo)卷(juan)簾(lian)門(men)的功(gong)能,且該防火(huo)(huo)卷(juan)簾(lian)門(men)提(ti)升(sheng)到位后應能自動(dong)恢復原關(guan)閉狀(zhuang)態。
3、防火卷簾門的報警系統
防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)應該設(she)有(you)自動(dong)(dong)報警控(kong)(kong)制(zhi)(zhi)系統的(de)(de)電動(dong)(dong)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)應設(she)有(you)自動(dong)(dong)關閉控(kong)(kong)制(zhi)(zhi)裝(zhuang)置,用(yong)于(yu)疏(shu)散通道上的(de)(de)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)應有(you)由探測器(qi)控(kong)(kong)制(zhi)(zhi)兩步(bu)下(xia)(xia)降(jiang)或下(xia)(xia)降(jiang)到1.5m~1.8m后(hou)延時下(xia)(xia)降(jiang)到底功能(neng)(neng);用(yong)于(yu)只起到防(fang)(fang)火(huo)(huo)分(fen)隔(ge)作用(yong)的(de)(de)卷(juan)簾(lian)(lian)(lian)(lian)(lian)應一步(bu)下(xia)(xia)降(jiang)到底,手動(dong)(dong)速放裝(zhuang)置,防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)手動(dong)(dong)速放裝(zhuang)置的(de)(de)臂力不大(da)于(yu)50N;消防(fang)(fang)控(kong)(kong)制(zhi)(zhi)室應有(you)強(qiang)制(zhi)(zhi)電動(dong)(dong)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)下(xia)(xia)降(jiang)功能(neng)(neng)(應急操作裝(zhuang)置)并(bing)顯示其狀(zhuang)態;安(an)裝(zhuang)在(zai)疏(shu)散通道上的(de)(de)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)的(de)(de)啟閉裝(zhuang)置應能(neng)(neng)在(zai)火(huo)(huo)災(zai)斷電后(hou)手動(dong)(dong)機(ji)械提升以(yi)下(xia)(xia)降(jiang)關閉的(de)(de)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men),并(bing)且該防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)能(neng)(neng)依靠其自重(zhong)(zhong)重(zhong)(zhong)新恢復(fu)原關閉狀(zhuang)態。手動(dong)(dong)防(fang)(fang)火(huo)(huo)卷(juan)簾(lian)(lian)(lian)(lian)(lian)門(men)(men)手動(dong)(dong)下(xia)(xia)放牽引(yin)力不大(da)于(yu)150N。
在防(fang)(fang)(fang)火(huo)卷(juan)簾門安(an)裝完之后一(yi)定要(yao)檢查一(yi)下(xia)以上(shang)的幾點設備及注意(yi)下(xia)事項,把消防(fang)(fang)(fang)中(zhong)控(kong)的信號線連接到防(fang)(fang)(fang)火(huo)卷(juan)簾門控(kong)制器上(shang)就完全(quan)的整個防(fang)(fang)(fang)火(huo)卷(juan)簾門消防(fang)(fang)(fang)聯(lian)動的功(gong)能。