【學員問題】輕鋼龍骨隔墻施工工藝?
【解答】工藝流程(cheng):
彈(dan)線、分檔—做地(di)枕帶(設計有要求(qiu)時)—固定(ding)沿(yan)頂、沿(yan)地(di)龍骨(gu)—固定(ding)邊框龍骨(gu)—安裝(zhuang)(zhuang)豎向龍骨(gu)—安裝(zhuang)(zhuang)門、窗框—安裝(zhuang)(zhuang)附(fu)加龍骨(gu)—安裝(zhuang)(zhuang)支撐龍骨(gu)—檢查龍骨(gu)安裝(zhuang)(zhuang)—電氣鋪管(guan)安附(fu)墻(qiang)設備(bei)—安裝(zhuang)(zhuang)一面(mian)罩面(mian)板—填充隔(ge)聲材料—安裝(zhuang)(zhuang)另一面(mian)罩面(mian)板—接(jie)縫(feng)及護角處理—質量檢驗
(1)彈(dan)線、分檔:在隔墻與(yu)上(shang)、下及(ji)(ji)兩邊基體的相接處,應按(an)(an)龍(long)骨(gu)的寬度彈(dan)線。彈(dan)線清(qing)楚,位置(zhi)準確。按(an)(an)設計要求,結合罩面板的長、寬分檔,以確定豎(shu)向龍(long)骨(gu);橫撐及(ji)(ji)附加龍(long)骨(gu)的位置(zhi)。
(2)作地枕(zhen)帶(dai)(dai):當設計有要求時,按設計要求作豆(dou)石(shi)混(hun)凝(ning)土地枕(zhen)帶(dai)(dai)。作地枕(zhen)帶(dai)(dai)應支模,豆(dou)石(shi)混(hun)凝(ning)土應澆(jiao)搗密(mi)實。
(3) 固(gu)定沿(yan)(yan)(yan)項、沿(yan)(yan)(yan)地龍骨(gu);沿(yan)(yan)(yan)彈線位(wei)置固(gu)定沿(yan)(yan)(yan)項、沿(yan)(yan)(yan)地龍骨(gu),可(ke)用射釘或(huo)膨脹螺(luo)栓固(gu)定,固(gu)定點間距應不大于600mm,龍骨(gu)對接(jie)應保(bao)持(chi)平直。
(4)固定邊框龍骨:沿彈線位置固定邊框龍骨,龍骨的邊線應與彈線重合。龍骨的端(duan)部應(ying)固(gu)定(ding)(ding),固(gu)定(ding)(ding)點間距應(ying)不(bu)大(da)于(yu)lm,固(gu)定(ding)(ding)應(ying)牢固(gu)。
(5)邊(bian)框(kuang)龍骨(gu)與(yu)基體之間,應按(an)設計要求安裝密封(feng)條。
(6)選用支撐(cheng)卡系列龍骨時,應先(xian)將支撐(cheng)卡安裝在豎(shu)向龍骨的開口上,卡距(ju)為400~600mm,距(ju)龍骨兩端的距(ju)離(li)為20~25mm.
(7)安裝豎向龍骨應垂(chui)直(zhi),龍骨間(jian)距應按設計要求布置。設計無要求時,其間(jian)距可按板寬確定,如(ru)板寬為(wei) 900mm、1200mm時,其間(jian)距分(fen)別為(wei) 453mm、603mm.
(8)選(xuan)用通貫系列龍骨時,低于(yu)3m的隔(ge)斷安(an)裝一道(dao);3~5m隔(ge)斷安(an)裝兩道(dao);5m以上(shang)安(an)裝三道(dao)。
(9)罩面板橫向(xiang)接縫處,如不在沿頂、沿地(di)龍骨上,應加橫撐龍骨固定板縫。
(10)門(men)窗或特殊節點處,使用附(fu)加龍骨,安裝(zhuang)應(ying)符合(he)設計要求。
(11)對于特殊結構的隔墻龍骨安裝(如曲面(mian)、斜面(mian)隔(ge)斷等),應符合設計(ji)要求。
(12)電氣鋪(pu)管、安(an)裝(zhuang)附墻(qiang)設(she)備:按圖紙要求(qiu)預埋管道和附墻(qiang)設(she)備。要求(qiu)與龍骨(gu)的安(an)裝(zhuang)同步(bu)進行,或在(zai)(zai)另一面罩面板封板前進行,并采取局部加強(qiang)措施,固定牢固。電氣設(she)備專業在(zai)(zai)墻(qiang)中鋪(pu)設(she)管線時,應避免切(qie)斷橫、豎向龍骨(gu),同時避免在(zai)(zai)沿(yan)墻(qiang)下端設(she)置管線。
(13)龍骨檢(jian)查校正補強:安裝罩面(mian)板前,應檢(jian)查隔斷骨架的牢固程度,門窗框、各種(zhong)附墻設(she)備、管(guan)道的安裝和(he)固定是(shi)否(fou)符合設(she)計要求。如有不牢固處(chu),應進行加固。龍骨的立面(mian)垂(chui)直偏差應≤3mm,表(biao)面(mian)不平整應≤2mm.
(14) 安裝罩面板:
1)罩面(mian)(mian)板宜豎(shu)向(xiang)鋪(pu)設,長邊(即包封(feng)邊)接(jie)縫應落在豎(shu)龍骨(gu)上。僅(jin)隔墻(qiang)為(wei)防火墻(qiang)時,罩面(mian)(mian)板應豎(shu)向(xiang)鋪(pu)設。曲(qu)面(mian)(mian)墻(qiang)所用(yong)罩面(mian)(mian)板宜橫向(xiang)鋪(pu)設。
2)龍(long)(long)骨兩側(ce)的(de)罩面板(ban)及龍(long)(long)骨一側(ce)的(de)內(nei)外兩層罩面板(ban)應錯縫排列,接縫不(bu)得落在同一根龍(long)(long)骨上。
3)膏板(ban)用(yong)自(zi)攻(gong)螺釘(ding)(ding)固定(ding)。沿(yan)罩(zhao)面板(ban)周邊(bian)螺釘(ding)(ding)間距(ju)不應大于(yu)200mm,中間部(bu)分螺釘(ding)(ding)間距(ju)不應大于(yu)300mm,螺釘(ding)(ding)與板(ban)邊(bian)緣(yuan)的距(ju)離應為(wei)10~16mm.
4)安裝罩(zhao)面(mian)板(ban)時(shi),應(ying)從(cong)板(ban)的中部向(xiang)板(ban)的四邊固定,釘頭略埋入板(ban)內,但(dan)不(bu)得損壞紙(zhi)面(mian)。釘眼應(ying)用(yong)石膏膩子(zi)抹平。
5)罩面板宜使用整板。如需對接時,應緊靠(kao),但不得強壓(ya)就位。
6)隔墻端部的罩面板與周圍的墻或柱應留有3mm的槽口。施工(gong)時(shi),先在槽口處加注嵌縫(feng)膏,然后鋪(pu)板,擠壓嵌縫(feng)膏使其(qi)和鄰(lin)近表層緊密接觸。
7)安裝防火(huo)墻罩面板(ban)時,罩面板(ban)不得(de)固(gu)定在沿(yan)(yan)頂(ding)、沿(yan)(yan)地龍骨上,應另設橫(heng)撐(cheng)龍骨加(jia)以(yi)固(gu)定。
8)隔(ge)墻板的下端如用木(mu)踢(ti)腳(jiao)(jiao)板覆蓋(gai),罩(zhao)面(mian)板應離地(di)面(mian)20~30mm;用大理(li)石、水磨石踢(ti)腳(jiao)(jiao)板時(shi),罩(zhao)面(mian)板下端應與踢(ti)腳(jiao)(jiao)板上口齊平(ping),接縫(feng)嚴(yan)密(mi)。
9)鋪放墻體內的玻(bo)璃棉(mian)。礦棉(mian)板、巖棉(mian)板等(deng)填(tian)充(chong)材料,與安裝另一側紙面(mian)罩面(mian)板同時進(jin)行,填(tian)充(chong)材料應鋪滿鋪平。
(15)接(jie)縫及護角處理:
1)紙面罩面板墻接縫(feng)做法有三種(zhong)形式,即平(ping)縫(feng)、凹縫(feng)和壓條(tiao)縫(feng)。一般做平(ping)縫(feng)較多,可按以下程序處理(li):
a.紙面(mian)罩面(mian)板安裝(zhuang)時,其接(jie)縫處應適當留縫(一般3~6mm),并必(bi)須坡口(kou)與坡口(kou)相(xiang)接(jie)。接(jie)縫內浮土清除干(gan)凈(jing)后(hou),刷一道50%濃度的107膠(jiao)水溶液(ye)。
b.用(yong)小刮(gua)刀把(ba)WKF接縫(feng)膩子(zi)嵌(qian)(qian)(qian)入板(ban)(ban)縫(feng),板(ban)(ban)縫(feng)要嵌(qian)(qian)(qian)滿嵌(qian)(qian)(qian)實,與波口刮(gua)平。待膩子(zi)干透后,檢查嵌(qian)(qian)(qian)縫(feng)處是否(fou)有裂紋產(chan)生(sheng)(sheng),如產(chan)生(sheng)(sheng)裂紋要分(fen)析原因,并(bing)重新嵌(qian)(qian)(qian)縫(feng)。
c.在接縫坡口處刮約lmm厚的WKF膩子(zi),然后(hou)粘貼玻纖帶,壓實刮平(ping)。
d.當膩子(zi)開始凝(ning)固又尚處于(yu)潮濕狀態時,再刮(gua)一道WKF膩子(zi),將玻(bo)纖帶埋入膩子(zi)中,并(bing)將板(ban)縫填滿刮(gua)平。
e.陰角的接縫處理方法同(tong)平縫。
2)陽(yang)角可(ke)按以下方法(fa)處(chu)理:
a.陽角(jiao)粘貼兩層玻纖布(bu)條,角(jiao)兩邊(bian)均拐過100mm,粘貼方法同(tong)平(ping)縫(feng)處理,表面亦用WKF膩子刮平(ping)。
b.當設計(ji)要求作金屬(shu)護角條時,按(an)設計(ji)要求的(de)部(bu)位、高度(du),先刮一層膩子,隨即(ji)用鍍鋅釘固定(ding)金屬(shu)護角條,并用膩子刮平。
(16)待板(ban)縫(feng)(feng)膩子干燥后,檢(jian)查板(ban)縫(feng)(feng)是否(fou)有裂(lie)縫(feng)(feng)產生(sheng),如發現裂(lie)紋,必須分析(xi)原因,采取有效的措施加以克(ke)服(fu),否(fou)則不能(neng)進(jin)入板(ban)面裝飾施工(gong)。
以上內容均(jun)根據(ju)學員實際工(gong)作中遇到的問題整(zheng)理而(er)成,供(gong)參考,如有問題請及時溝通(tong)、指正。