一、高壓母線槽是什么
高壓母線槽是(shi)運用(yong)于(yu)大(da)型(xing)變電(dian)(dian)(dian)(dian)站(zhan)、供(gong)電(dian)(dian)(dian)(dian)系統、大(da)型(xing)企(qi)業的(de)(de)自備電(dian)(dian)(dian)(dian)廠中(zhong)。它是(shi)以(yi)取代傳統的(de)(de)裸(luo)排走(zou)線方式,除(chu)具有安全、美觀、可(ke)靠的(de)(de)特點外,還因(yin)高(gao)壓母線槽外殼是(shi)封閉的(de)(de),可(ke)以(yi)大(da)大(da)減少停電(dian)(dian)(dian)(dian)檢修次數,在輸(shu)送(song)較大(da)電(dian)(dian)(dian)(dian)流時,可(ke)消除(chu)用(yong)雙拼、三(san)拼高(gao)壓電(dian)(dian)(dian)(dian)纜所帶(dai)來(lai)的(de)(de)因(yin)電(dian)(dian)(dian)(dian)流分配不平衡而引起的(de)(de)故障。確保(bao)供(gong)電(dian)(dian)(dian)(dian)的(de)(de)可(ke)靠性。可(ke)廣(guang)泛用(yong)于(yu)10KV以(yi)下,2000A以(yi)內的(de)(de)輸(shu)電(dian)(dian)(dian)(dian)系統。
二、高壓母線槽的工作原理
高(gao)壓(ya)(ya)(ya)母(mu)(mu)線(xian)槽采用(yong)了高(gao)強(qiang)度(du)、高(gao)性(xing)(xing)(xing)能(neng)的DMC絕緣支塊夾(jia)緊式(shi)結構,具有良好的負載性(xing)(xing)(xing)能(neng)和動(dong)熱(re)穩定性(xing)(xing)(xing);過載能(neng)力強(qiang)、溫(wen)升低(di)。為加強(qiang)絕緣型(xing)全(quan)封(feng)閉式(shi)高(gao)壓(ya)(ya)(ya)母(mu)(mu)線(xian)槽,防護等級IP40,導電(dian)體由(you)高(gao)壓(ya)(ya)(ya)熱(re)收縮套(tao)管全(quan)長(chang)塑封(feng),使用(yong)地區海拔高(gao)可達2000m。高(gao)壓(ya)(ya)(ya)母(mu)(mu)線(xian)槽取代傳(chuan)統(tong)的裸排走線(xian)方(fang)式(shi),采取封(feng)閉式(shi)封(feng)裝,可以大大減(jian)少停(ting)電(dian)檢修(xiu)次數,在(zai)輸送(song)較大電(dian)流時,可消除(chu)用(yong)雙拼、三拼高(gao)壓(ya)(ya)(ya)電(dian)纜所帶來的因電(dian)流分配(pei)不平衡(heng)而(er)引(yin)起(qi)的故障(zhang)。確保供電(dian)的可靠性(xing)(xing)(xing)。
三、高壓母線槽的修理維護
1、高壓母線槽長期(qi)運行時至少每(mei)年定期(qi)檢修(xiu)一(yi)次。
2、檢查總的負(fu)載電流(liu)不得超過設計電流(liu)和(he)主母線槽(cao)的額定(ding)電流(liu)。
3、高壓(ya)母線(xian)槽(cao)檢(jian)修前需對母線(xian)槽(cao)系(xi)統進(jin)行停(ting)電(dian)檢(jian)查!完全切斷母線(xian)槽(cao)所有電(dian)源!并(bing)用萬用電(dian)表測量導電(dian)體有無電(dian)壓(ya),確(que)認母線(xian)槽(cao)系(xi)統未帶電(dian)方(fang)可例行檢(jian)修。防止高電(dian)壓(ya)對操作人員構成(cheng)身(shen)體傷害甚(shen)至(zhi)死亡的嚴重事故!
4、高壓母(mu)線(xian)槽運行中,應(ying)不間斷查看整條(tiao)系統(tong)的四周是否(fou)存在滲漏、噴水(shui)、潛在潮(chao)氣源,是否(fou)存在對系統(tong)構成威脅的重(zhong)物,以及對母(mu)線(xian)槽系統(tong)溫升構成影(ying)響的熱源,檢查有(you)(you)無異(yi)物進入母(mu)線(xian)槽內部。檢查母(mu)線(xian)槽系統(tong)零部件有(you)(you)無缺損、銹蝕現象(xiang)、支架彈簧是否(fou)有(you)(you)合適的彈力,發現問(wen)題(ti)后立(li)即(ji)更換。
5、高(gao)壓母線槽(cao)長期運行(xing)時每年(nian)定期檢(jian)(jian)(jian)測一次接(jie)(jie)(jie)頭(tou)溫(wen)升,接(jie)(jie)(jie)頭(tou)溫(wen)升按照GB7251標準不(bu)超過70K為合格(環境溫(wen)度為40℃)。檢(jian)(jian)(jian)查(cha)(cha)(cha)所有(you)(you)母線槽(cao)接(jie)(jie)(jie)頭(tou)連接(jie)(jie)(jie)螺栓(shuan)及導電體接(jie)(jie)(jie)觸部分(fen)是(shi)否有(you)(you)松(song)動(dong)現象(xiang)(xiang)。防(fang)止因松(song)動(dong)產(chan)生的(de)(de)阻值增高(gao)而使接(jie)(jie)(jie)頭(tou)產(chan)生發(fa)熱現象(xiang)(xiang)。檢(jian)(jian)(jian)查(cha)(cha)(cha)絕(jue)緣(yuan)材料是(shi)否有(you)(you)老化(hua)現象(xiang)(xiang)。導電部分(fen)是(shi)否有(you)(you)熔化(hua)變(bian)形現象(xiang)(xiang)。如發(fa)現有(you)(you)相間(jian)接(jie)(jie)(jie)地、絕(jue)緣(yuan)擊(ji)穿現象(xiang)(xiang),應分(fen)段(duan)拆除(chu)并(bing)用耐壓測試(shi)儀分(fen)段(duan)檢(jian)(jian)(jian)查(cha)(cha)(cha),找出故(gu)障,或重新(xin)(xin)更換母線槽(cao),或重新(xin)(xin)進行(xing)絕(jue)緣(yuan)包覆處(chu)理。檢(jian)(jian)(jian)查(cha)(cha)(cha)母線槽(cao)系統的(de)(de)插接(jie)(jie)(jie)箱插腳(jiao)與母排(pai)接(jie)(jie)(jie)觸是(shi)否良好。
6、定期清除母線槽(cao)系統表面積塵(chen),確保散熱良好。
7、母線槽系統檢修(xiu)完(wan)畢(bi),重(zhong)新送(song)電前,應檢查絕緣電阻(zu)并有完(wan)整(zheng)的檢修(xiu)記錄。