南北方暖氣片采暖區別
1、間歇式采暖要增大暖氣片數量
北(bei)方(fang)為(wei)集(ji)中供暖(nuan)(nuan)(nuan),南(nan)方(fang)采(cai)暖(nuan)(nuan)(nuan)多為(wei)壁掛(gua)爐(lu)獨(du)立采(cai)暖(nuan)(nuan)(nuan)。壁掛(gua)爐(lu)獨(du)立采(cai)暖(nuan)(nuan)(nuan)的優勢在于(yu)可(ke)以實現(xian)隨意(yi)調節(jie)供暖(nuan)(nuan)(nuan)溫度,有(you)利(li)于(yu)節(jie)約能源和采(cai)暖(nuan)(nuan)(nuan)費用(yong)。獨(du)立采(cai)暖(nuan)(nuan)(nuan)用(yong)戶,可(ke)以分為(wei)兩種(zhong)(zhong),一種(zhong)(zhong)是(shi)上(shang)班族,白(bai)天家里(li)沒人,晚上(shang)有(you)人,用(yong)時即(ji)開(kai)(kai),不用(yong)即(ji)關。為(wei)了實現(xian)暖(nuan)(nuan)(nuan)氣片(pian)開(kai)(kai)啟后房間的迅速升溫,對于(yu)此類用(yong)戶,在選(xuan)型(xing)時必須(xu)考慮一定程度的放大,增加暖(nuan)(nuan)(nuan)氣片(pian)片(pian)數;另一種(zhong)(zhong)是(shi)家里(li)一直有(you)人,采(cai)暖(nuan)(nuan)(nuan)系(xi)統基(ji)本上(shang)是(shi)全天24小時要開(kai)(kai)啟使用(yong),這種(zhong)(zhong)客戶基(ji)本上(shang)按照正常選(xuan)型(xing)即(ji)可(ke)。
2、合理選擇暖氣片的數量
暖氣片(pian)的設(she)計(ji)數(shu)量(liang)與(yu)單位面積熱(re)負(fu)(fu)荷(he)成(cheng)反比。在(zai)(zai)北方新建建筑一(yi)般(ban)執行65%的節能標(biao)準,住宅(zhai)設(she)計(ji)熱(re)負(fu)(fu)荷(he)一(yi)般(ban)為45-50W/平米。在(zai)(zai)南方,許多(duo)暖通公(gong)司(si)一(yi)般(ban)在(zai)(zai)設(she)計(ji)時都以經驗值100-150W來(lai)選擇。作為影響房價(jia)熱(re)負(fu)(fu)荷(he)的參數(shu)很多(duo),包括圍護結(jie)構,冷風(feng)滲透、冷風(feng)侵入、層高、朝向、地區差異等諸多(duo)因素組成(cheng)。
南方(fang)(fang)(fang)采(cai)暖(nuan)熱(re)負荷之所以(yi)大,主要是(shi)(shi)原因(yin)有(you)二(er):首(shou)先是(shi)(shi)因(yin)為(wei)南方(fang)(fang)(fang)圍護結構保溫(wen)性能很差,不(bu)(bu)像北方(fang)(fang)(fang)建筑有(you)外墻保溫(wen)或內保溫(wen);第二(er)個原因(yin)是(shi)(shi)南方(fang)(fang)(fang)采(cai)暖(nuan)戶基(ji)本屬(shu)于(yu)采(cai)暖(nuan)孤島(dao),即自家采(cai)暖(nuan),而上下左右的(de)鄰(lin)居均(jun)未采(cai)暖(nuan),因(yin)此(ci)存在很大的(de)鄰(lin)間傳熱(re)熱(re)損失。故(gu)要加大設(she)計熱(re)負荷。而北方(fang)(fang)(fang)均(jun)為(wei)集中供(gong)暖(nuan),很少(shao)存在鄰(lin)間傳熱(re)問題。以(yi)上兩點決定,南方(fang)(fang)(fang)采(cai)暖(nuan)熱(re)負荷較大,不(bu)(bu)能盲目照(zhao)搬(ban)北方(fang)(fang)(fang)集中供(gong)暖(nuan)。
熱(re)負荷(he)計算經(jing)驗(yan)值(zhi):南方地區冬天(tian)平均最低氣溫高(gao)于(yu)5攝(she)氏(shi)度(du)(du)時,單位(wei)(wei)面(mian)積熱(re)負荷(he)基(ji)準(zhun)值(zhi)100W,冬天(tian)平均最低氣溫低于(yu)5攝(she)氏(shi)度(du)(du)時,單位(wei)(wei)面(mian)積熱(re)負荷(he)基(ji)準(zhun)值(zhi)為110W。
修正系數:外(wai)墻窗墻比大于(yu)1時,基準(zhun)值+10:
修正系數:外墻(qiang)為(wei)非(fei)保溫墻(qiang)體時,基準值+10;
修正系(xi)數:外(wai)墻≥兩(liang)面墻體時,基準值+10;
修正系數:朝向為北向時,基準值+10;
修正系數:層(ceng)高≥3m,基(ji)準(zhun)值+10;
說明:次估算法為(wei)非準(zhun)確值,只(zhi)是給大家提供(gong)一個(ge)經驗值的參考,如果比較較真的朋友(you)就(jiu)不要參與探討啦。
3、暖氣片實際工況下的散熱量
暖(nuan)氣(qi)片的(de)(de)(de)(de)散熱(re)(re)量(liang)是(shi)(shi)(shi)(shi)一個動態變(bian)化的(de)(de)(de)(de)過程,它(ta)根據進出(chu)水(shui)(shui)(shui)的(de)(de)(de)(de)水(shui)(shui)(shui)溫(wen)(wen)(wen)的(de)(de)(de)(de)不(bu)同(tong)而(er)不(bu)同(tong),不(bu)是(shi)(shi)(shi)(shi)一個固定的(de)(de)(de)(de)數值。供(gong)暖(nuan)暖(nuan)氣(qi)片按(an)我(wo)國國家標準(zhun)GB/T13754-2008在(zai)(zai)閉式(shi)小區(qu)按(an)規定條件所測得的(de)(de)(de)(de)散熱(re)(re)量(liang),單位是(shi)(shi)(shi)(shi)瓦(W)。規定條件是(shi)(shi)(shi)(shi):熱(re)(re)媒(mei)為熱(re)(re)水(shui)(shui)(shui),進水(shui)(shui)(shui)溫(wen)(wen)(wen)度(du)(du)(du)是(shi)(shi)(shi)(shi)95攝氏(shi)度(du)(du)(du),出(chu)水(shui)(shui)(shui)溫(wen)(wen)(wen)度(du)(du)(du)70攝氏(shi)度(du)(du)(du),平(ping)均水(shui)(shui)(shui)溫(wen)(wen)(wen)是(shi)(shi)(shi)(shi)(95+70)/2=82.5℃,室(shi)溫(wen)(wen)(wen)是(shi)(shi)(shi)(shi)18攝氏(shi)度(du)(du)(du),計算(suan)溫(wen)(wen)(wen)差(cha)△T=82.5℃-18℃=64.5℃。在(zai)(zai)此工(gong)況(kuang)下(xia)得出(chu)的(de)(de)(de)(de)散熱(re)(re)量(liang)稱為標準(zhun)散熱(re)(re)量(liang)。而(er)在(zai)(zai)壁掛爐獨立采暖(nuan)系統(tong)中,通常(chang)暖(nuan)氣(qi)片的(de)(de)(de)(de)出(chu)水(shui)(shui)(shui)溫(wen)(wen)(wen)度(du)(du)(du)在(zai)(zai)80左(zuo)右(you)。回(hui)水(shui)(shui)(shui)溫(wen)(wen)(wen)度(du)(du)(du)在(zai)(zai)60-65度(du)(du)(du)左(zuo)右(you)。△T==50℃左(zuo)右(you),基本等于歐洲的(de)(de)(de)(de)EN422標準(zhun)。在(zai)(zai)此工(gong)況(kuang)下(xia)的(de)(de)(de)(de)散熱(re)(re)量(liang)才是(shi)(shi)(shi)(shi)暖(nuan)氣(qi)片的(de)(de)(de)(de)實際散熱(re)(re)量(liang)。一般廠(chang)家的(de)(de)(de)(de)樣本里都是(shi)(shi)(shi)(shi)有這(zhe)兩個工(gong)況(kuang),我(wo)們注(zhu)意選型(xing)時根據選擇(ze)出(chu)來(lai)的(de)(de)(de)(de)熱(re)(re)負(fu)荷,取暖(nuan)氣(qi)片△T=50℃的(de)(de)(de)(de)實際工(gong)況(kuang)來(lai)予以選擇(ze)。
4、暖氣片的安裝位置
暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)取(qu)(qu)暖(nuan)(nuan)(nuan)效(xiao)果(guo)(guo)主要(yao)是依(yi)靠對(dui)流(liu)和輻(fu)射(she)(she)兩種散熱(re)方(fang)式而取(qu)(qu)得的(de),所(suo)以一定要(yao)保證(zheng)暖(nuan)(nuan)(nuan)氣(qi)(qi)片上(shang)下(xia)左右空氣(qi)(qi)流(liu)通和輻(fu)射(she)(she)的(de)方(fang)便,不要(yao)放(fang)在沙發后面(mian)(mian)或者窗(chuang)簾后面(mian)(mian),這樣暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)取(qu)(qu)暖(nuan)(nuan)(nuan)效(xiao)果(guo)(guo)將會大打折扣。盡量(liang)將暖(nuan)(nuan)(nuan)氣(qi)(qi)片安裝在窗(chuang)臺下(xia)方(fang),但是現在許(xu)多人又(you)采用了落地窗(chuang)簾,當(dang)窗(chuang)簾拉上(shang)后,這時(shi)暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)取(qu)(qu)暖(nuan)(nuan)(nuan)效(xiao)果(guo)(guo)就相(xiang)當(dang)差。另外,單組(zu)暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)供熱(re)面(mian)(mian)積一般建議(yi)不要(yao)超(chao)過20平米,當(dang)采暖(nuan)(nuan)(nuan)面(mian)(mian)積較大超(chao)出時(shi),則以此(ci)原理(li)增(zeng)加暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)片數(shu),并(bing)分(fen)為兩組(zu)對(dui)角擺放(fang),以增(zeng)加暖(nuan)(nuan)(nuan)氣(qi)(qi)片的(de)對(dui)流(liu)效(xiao)果(guo)(guo),保證(zheng)整體取(qu)(qu)暖(nuan)(nuan)(nuan)的(de)溫差梯度(du)較小,提高室內溫度(du)場的(de)均(jun)勻性。