一、如何檢定爐溫測試儀
爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)是工業(ye)生(sheng)產中常用的(de)測量(liang)設(she)備,可(ke)以用于測量(liang)鍋爐(lu)(lu)(lu)、窯爐(lu)(lu)(lu)、熱處理爐(lu)(lu)(lu)等(deng)設(she)備的(de)溫(wen)(wen)(wen)度(du),為(wei)(wei)(wei)保證爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)的(de)測量(liang)精度(du),必須對(dui)其進(jin)(jin)(jin)行(xing)(xing)定(ding)(ding)(ding)期的(de)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)和校(xiao)(xiao)準(zhun)(zhun):1、爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)的(de)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)方法:(1)外觀檢(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha):首先對(dui)爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)的(de)外觀進(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha),確(que)保其外表(biao)(biao)無破損(sun)、變形(xing)等(deng)異常情況(kuang)。(2)環(huan)境(jing)適應(ying)性檢(jian)(jian)(jian)(jian)(jian)(jian)查(cha)(cha):將爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)置于環(huan)境(jing)溫(wen)(wen)(wen)度(du)為(wei)(wei)(wei)20℃±5℃、相對(dui)濕(shi)度(du)為(wei)(wei)(wei)不(bu)超(chao)過80%的(de)環(huan)境(jing)中,并(bing)保持(chi)一定(ding)(ding)(ding)時(shi)(shi)間后進(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)測,確(que)保其儀(yi)(yi)表(biao)(biao)指(zhi)針(zhen)或數(shu)字顯示與標(biao)準(zhun)(zhun)溫(wen)(wen)(wen)度(du)相符。(3)基(ji)本誤差(cha)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding):使(shi)用標(biao)準(zhun)(zhun)爐(lu)(lu)(lu)對(dui)爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)進(jin)(jin)(jin)行(xing)(xing)基(ji)本誤差(cha)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding),采用兩種不(bu)同(tong)溫(wen)(wen)(wen)度(du)點進(jin)(jin)(jin)行(xing)(xing)校(xiao)(xiao)準(zhun)(zhun),分別為(wei)(wei)(wei)200℃和500℃。校(xiao)(xiao)準(zhun)(zhun)要求(qiu)誤差(cha)為(wei)(wei)(wei)±0.5℃。(4)穩定(ding)(ding)(ding)性檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding):將爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)置于標(biao)準(zhun)(zhun)溫(wen)(wen)(wen)度(du)下(xia),保持(chi)一定(ding)(ding)(ding)時(shi)(shi)間后進(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)測,與第3步的(de)測量(liang)值(zhi)進(jin)(jin)(jin)行(xing)(xing)比對(dui),誤差(cha)要求(qiu)小于±0.5℃。(5)重復性檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding):在相同(tong)條件下(xia)進(jin)(jin)(jin)行(xing)(xing)多次(ci)測定(ding)(ding)(ding),并(bing)對(dui)不(bu)同(tong)測量(liang)結果進(jin)(jin)(jin)行(xing)(xing)比對(dui),誤差(cha)要求(qiu)小于±0.5℃。2、爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)要求(qiu):(1)儀(yi)(yi)器檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)周期為(wei)(wei)(wei)1年(nian)。(2)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)時(shi)(shi)應(ying)嚴(yan)格(ge)按(an)照(zhao)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)方法進(jin)(jin)(jin)行(xing)(xing)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)和校(xiao)(xiao)準(zhun)(zhun),確(que)保校(xiao)(xiao)準(zhun)(zhun)的(de)精度(du)和可(ke)靠性。(3)對(dui)于檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)不(bu)合格(ge)的(de)爐(lu)(lu)(lu)溫(wen)(wen)(wen)測試(shi)儀(yi)(yi),應(ying)及(ji)時(shi)(shi)進(jin)(jin)(jin)行(xing)(xing)修(xiu)理、調整(zheng)或更換(huan)。(4)檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)結果應(ying)記錄(lu)在檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)記錄(lu)表(biao)(biao)中,檢(jian)(jian)(jian)(jian)(jian)(jian)定(ding)(ding)(ding)記錄(lu)表(biao)(biao)應(ying)保存至少(shao)10年(nian)。
二、爐溫測試儀怎么刪除記錄
爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀是工業生產(chan)中常用的一(yi)種溫(wen)度(du)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)設(she)備(bei),它可以測(ce)(ce)(ce)(ce)(ce)量高溫(wen)環境下(xia)的溫(wen)度(du)變化,并且可以記(ji)錄溫(wen)度(du)數(shu)據(ju)(ju),有的爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀會(hui)自動覆(fu)蓋老的數(shu)據(ju)(ju)記(ji)錄,有的則需(xu)要手動刪(shan)除(chu)(chu)(chu),一(yi)般爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀刪(shan)除(chu)(chu)(chu)記(ji)錄方法步驟是:1、打(da)開爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀,并連接到電腦。2、在電腦上安裝爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀的驅動程序,確保(bao)電腦能夠(gou)識別爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀。3、打(da)開爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀軟(ruan)(ruan)件(jian),在軟(ruan)(ruan)件(jian)中找到爐(lu)(lu)(lu)(lu)溫(wen)數(shu)據(ju)(ju)的存儲位置。4、選中需(xu)要清(qing)理的數(shu)據(ju)(ju)文(wen)件(jian),右鍵點擊文(wen)件(jian),并選擇“刪(shan)除(chu)(chu)(chu)”。5、在彈出對(dui)話框中確認刪(shan)除(chu)(chu)(chu)操作(zuo)。完成(cheng)后,爐(lu)(lu)(lu)(lu)溫(wen)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)(shi)儀里的數(shu)據(ju)(ju)記(ji)錄就被(bei)刪(shan)除(chu)(chu)(chu)干凈了。
三、爐溫測試儀價格多少錢一臺
一般來說,爐溫測試儀的價格與它的生產廠家、性能參數、測量范圍、尺寸大小等多方面因素有關,市場價有高有低,從兩三千元一臺到幾萬元一臺都有。選擇爐溫測試儀時,應綜合考慮多個方面,選擇適合生產需要的爐溫跟蹤系統,主要考慮的因素包括產品制程的需要、參數、物理尺寸、電池、無鉛制程、穩定性、精確性等方面,如果您有采購的需要,建議先來了解一下爐溫測試儀十大品牌。
四、爐溫測試儀使用教程
1、將(jiang)爐(lu)(lu)溫(wen)測(ce)試儀(yi)(yi)(yi)(yi)同(tong)外(wai)置(zhi)PCB連(lian)線(xian)按(an)插頭編(bian)號連(lian)接好(hao)(hao),同(tong)時(shi)準備好(hao)(hao)手套和(he)(he)隔(ge)(ge)(ge)熱(re)盒(he)(he)。2、將(jiang)爐(lu)(lu)溫(wen)測(ce)試儀(yi)(yi)(yi)(yi)通過(guo)數(shu)(shu)據(ju)(ju)(ju)線(xian)連(lian)接在電(dian)腦(nao)上,輕按(an)一下測(ce)溫(wen)儀(yi)(yi)(yi)(yi)上的“MODE”鍵,讓(rang)“Status"紅(hong)燈(deng)慢閃。3、用鼠標左鍵依(yi)次單(dan)擊(ji)測(ce)試儀(yi)(yi)(yi)(yi)的配套應(ying)用程序(xu)窗口中(zhong)的“連(lian)線(xian)變更(geng)”和(he)(he)“連(lian)線(xian)申(shen)請(qing)”以清除(chu)爐(lu)(lu)溫(wen)測(ce)試儀(yi)(yi)(yi)(yi)中(zhong)存(cun)儲的溫(wen)度(du)數(shu)(shu)據(ju)(ju)(ju),確定“電(dian)腦(nao)”窗口中(zhong)所顯(xian)示的電(dian)量大于60%。4、斷開(kai)測(ce)溫(wen)儀(yi)(yi)(yi)(yi)與電(dian)腦(nao)的連(lian)接,在回流焊(han)(han)爐(lu)(lu)前(qian),將(jiang)測(ce)溫(wen)儀(yi)(yi)(yi)(yi)放入(ru)隔(ge)(ge)(ge)熱(re)盒(he)(he),輕按(an)“MODE”按(an)鈕,見(jian)“Status”紅(hong)燈(deng)快(kuai)閃時(shi),迅速(su)關上隔(ge)(ge)(ge)熱(re)盒(he)(he)蓋,并(bing)將(jiang)外(wai)置(zhi)PCB和(he)(he)隔(ge)(ge)(ge)熱(re)蓋一同(tong)放在回流焊(han)(han)爐(lu)(lu)的鋼網上,使(shi)PCB和(he)(he)隔(ge)(ge)(ge)熱(re)盒(he)(he)保持至少十公分(fen)的距離(li)。5、在回流焊(han)(han)爐(lu)(lu)未端等待PCB及隔(ge)(ge)(ge)熱(re)盒(he)(he)出爐(lu)(lu)后,迅速(su)打(da)開(kai)隔(ge)(ge)(ge)熱(re)盒(he)(he)蓋,輕按(an)一下“MODE”鍵,使(shi)“Status”紅(hong)燈(deng)恢復(fu)慢閃,此(ci)時(shi)爐(lu)(lu)溫(wen)儀(yi)(yi)(yi)(yi)已(yi)停止讀取數(shu)(shu)據(ju)(ju)(ju),且爐(lu)(lu)溫(wen)數(shu)(shu)據(ju)(ju)(ju)已(yi)存(cun)入(ru)其存(cun)儲器中(zhong)。6、將(jiang)爐(lu)(lu)溫(wen)測(ce)試儀(yi)(yi)(yi)(yi)中(zhong)的溫(wen)度(du)數(shu)(shu)據(ju)(ju)(ju)下載到電(dian)腦(nao)中(zhong),分(fen)析溫(wen)度(du)曲線(xian)的合理(li)性,可行則打(da)印,不(bu)行則及時(shi)調整爐(lu)(lu)溫(wen)。