一、儲能變流器的結構
儲能變流器(Energy Storage Inverter,簡稱(cheng)ESI)通常由以下幾部分構成:
直(zhi)流(liu)側:包(bao)括電(dian)池組、充電(dian)器、直(zhi)流(liu)開關(guan)和直(zhi)流(liu)濾波(bo)電(dian)容等(deng)。
逆(ni)變(bian)(bian)器:包括逆(ni)變(bian)(bian)器橋、逆(ni)變(bian)(bian)控制(zhi)器、PWM模塊、濾(lv)波電容和輸出變(bian)(bian)壓器等。
控(kong)制系統(tong):包括功率(lv)控(kong)制器(qi)、電網連接控(kong)制器(qi)、電池管理系統(tong)(BMS)等。
通信模塊(kuai):用于與上(shang)位機(ji)進行通信、監控和遠程控制(zhi)等。
下面對(dui)各部分進行詳細介紹:
1、直(zhi)(zhi)(zhi)流(liu)(liu)側:電(dian)(dian)(dian)池組(zu)是(shi)儲能(neng)變流(liu)(liu)器的(de)核心部(bu)件(jian),用于儲存電(dian)(dian)(dian)能(neng)。充電(dian)(dian)(dian)器用于將電(dian)(dian)(dian)網中(zhong)的(de)交流(liu)(liu)電(dian)(dian)(dian)轉換為直(zhi)(zhi)(zhi)流(liu)(liu)電(dian)(dian)(dian),并充電(dian)(dian)(dian)到電(dian)(dian)(dian)池組(zu)中(zhong)。直(zhi)(zhi)(zhi)流(liu)(liu)開關用于控制電(dian)(dian)(dian)池組(zu)與逆變器的(de)連接和斷開。直(zhi)(zhi)(zhi)流(liu)(liu)濾波電(dian)(dian)(dian)容用于平滑直(zhi)(zhi)(zhi)流(liu)(liu)側電(dian)(dian)(dian)壓,并減(jian)小電(dian)(dian)(dian)流(liu)(liu)的(de)諧波。
2、逆(ni)(ni)變(bian)器(qi):逆(ni)(ni)變(bian)器(qi)橋(qiao)(qiao)是(shi)將(jiang)直流(liu)電(dian)轉換為交流(liu)電(dian)的核心(xin)部件(jian),其結(jie)構一般采用(yong)全橋(qiao)(qiao)式或半橋(qiao)(qiao)式。逆(ni)(ni)變(bian)控(kong)制器(qi)負責(ze)控(kong)制逆(ni)(ni)變(bian)器(qi)橋(qiao)(qiao)的開(kai)關(guan)管(guan),使其按照一定的PWM模式進行開(kai)關(guan),從(cong)而實現對輸出(chu)(chu)(chu)電(dian)壓、電(dian)流(liu)和(he)頻率等(deng)參數的控(kong)制。濾波(bo)電(dian)容用(yong)于減(jian)小(xiao)輸出(chu)(chu)(chu)電(dian)壓的諧波(bo),提高(gao)電(dian)路(lu)的效率和(he)穩定性。輸出(chu)(chu)(chu)變(bian)壓器(qi)用(yong)于將(jiang)輸出(chu)(chu)(chu)電(dian)壓調整到所需的電(dian)壓等(deng)級。
3、控制(zhi)系統(tong):功率控制(zhi)器(qi)用于(yu)控制(zhi)逆變(bian)器(qi)的輸出功率,以(yi)滿足負載需求。電(dian)(dian)網連(lian)接控制(zhi)器(qi)用于(yu)控制(zhi)儲能變(bian)流器(qi)與電(dian)(dian)網的連(lian)接和(he)斷開(kai),以(yi)保證電(dian)(dian)網的穩(wen)定性和(he)安全性。BMS用于(yu)對(dui)電(dian)(dian)池(chi)組的充放電(dian)(dian)過程(cheng)進行管(guan)理和(he)控制(zhi),以(yi)避免過充或(huo)過放等(deng)不(bu)良影響,從而保護電(dian)(dian)池(chi)和(he)延長其使(shi)用壽命。
4、通信模塊(kuai):用(yong)于(yu)與上(shang)位(wei)機進行通信、監控和(he)遠(yuan)程控制等,可(ke)(ke)以實現儲(chu)能(neng)變流器(qi)的遠(yuan)程監控和(he)控制,提高儲(chu)能(neng)系統的可(ke)(ke)靠性和(he)安全性。
總之,儲能變(bian)流器通(tong)過以上幾部(bu)分構成,能夠(gou)實現對(dui)電能的(de)高(gao)效轉換、儲存(cun)和調節,具有(you)廣泛的(de)應(ying)用前景。
二、儲能變流器的參數有哪些
儲能變流器的(de)參(can)數有九大類:直(zhi)流(liu)輸入(ru)參(can)數、電池參(can)數、輸出參(can)數(并(bing)網(wang)(wang))、輸出參(can)數(離網(wang)(wang))、通訊情況(kuang)、基本(ben)參(can)數、逆(ni)變(bian)器(qi)保護、逆(ni)變(bian)器(qi)效(xiao)率(lv)、法規及標準。
以最(zui)常用(yong)的單相(xiang)儲能(neng)機(ji)型為(wei)例。
1、直流輸入參數
儲能機(ji)直流(liu)(liu)側共2路輸入組串(chuan)(chuan),2路MPP追蹤,每(mei)串(chuan)(chuan)最(zui)大輸入電(dian)流(liu)(liu)為(wei)11A,最(zui)大輸入電(dian)壓(ya)(ya)(ya)為(wei)580V,MPPT工作電(dian)壓(ya)(ya)(ya)范圍(wei)為(wei)125~550V,在組串(chuan)(chuan)數(shu)量(liang)設(she)計的(de)時(shi)候,要考慮到到組串(chuan)(chuan)的(de)開路電(dian)壓(ya)(ya)(ya)不要超過580V(考慮現(xian)場極限溫度),工作電(dian)壓(ya)(ya)(ya)在125~550V之間,建議額定工作電(dian)壓(ya)(ya)(ya)在360V;若(ruo)采用285W的(de)板子,建議使用20~22塊,組件容量(liang)為(wei)5.70~6.27kWp為(wei)宜)。
2、電池參數
電池的(de)電壓為48V(額(e)定電壓),如果用(yong)戶使用(yong)了2V,12V等電壓的(de)鉛酸電池,可以通過(guo)串聯(lian)多塊電池的(de)方式(shi)得到48V的(de)電壓。
電(dian)(dian)池(chi)的(de)容量跟電(dian)(dian)池(chi)的(de)數量、單塊電(dian)(dian)池(chi)的(de)安時數有關,在選擇電(dian)(dian)池(chi)容量的(de)時候要合(he)理選型,最常見的(de)辦法(fa)是(shi)根(gen)據用戶側(ce)的(de)負載大(da)小、用電(dian)(dian)時長(chang)來計算電(dian)(dian)池(chi)容量;如果負載比(bi)較大(da)或者用電(dian)(dian)情(qing)況(kuang)復雜,可(ke)以考慮到儲能(neng)機1~2天(tian)光(guang)伏發(fa)電(dian)(dian)的(de)能(neng)力來配置電(dian)(dian)池(chi)。
電(dian)池(chi)的選(xuan)型(xing)一(yi)(yi)般要考慮電(dian)池(chi)的壽(shou)命、放(fang)電(dian)深(shen)度、循環次數等因素,鉛(qian)酸(suan)電(dian)池(chi)價格較(jiao)(jiao)為便(bian)宜,但(dan)是電(dian)池(chi)的壽(shou)命相對較(jiao)(jiao)短,DOD深(shen)度較(jiao)(jiao)低,且鉛(qian)酸(suan)電(dian)池(chi)組充放(fang)電(dian)沒有BMS協(xie)議管理(li),存在不一(yi)(yi)致性(xing),可能出現(xian)電(dian)池(chi)鼓(gu)包(bao)等現(xian)象,故(gu)不推薦使用(yong);鋰電(dian)池(chi)價格較(jiao)(jiao)為昂(ang)貴,但(dan)由于有BMS協(xie)議進行充放(fang)電(dian)的管理(li),一(yi)(yi)般壽(shou)命較(jiao)(jiao)長。
電(dian)池(chi)的(de)(de)接線:ES電(dian)池(chi)輸入的(de)(de)充放電(dian)電(dian)流可達直流100A,考(kao)慮到(dao)電(dian)池(chi)到(dao)逆變器的(de)(de)參數(shu),一(yi)般選用25mm的(de)(de)直流線纜。
3、輸出參數(并網)
儲能逆變(bian)器有(you)兩個(ge)輸出端:
一個是并網輸(shu)出端,又叫on-grid端;
另一個離網輸出端,又叫back-up輸出端。
并(bing)網(wang)(wang)輸出(chu)端(duan)一(yi)定要接電網(wang)(wang)才有(you)輸出(chu),在并(bing)網(wang)(wang)端(duan)和電網(wang)(wang)之間可以接負載,叫(jiao)做并(bing)網(wang)(wang)端(duan)負載;
當電(dian)網斷(duan)電(dian)的(de)時候(hou),這些負(fu)(fu)載不(bu)能工作(防孤島保護)。當電(dian)網有電(dian)的(de)時候(hou),光伏(fu)會優先供負(fu)(fu)載使用,光伏(fu)不(bu)夠的(de)時候(hou),電(dian)網予以(yi)補充,對負(fu)(fu)載的(de)容量沒有限制(zhi)。
4、輸出參數(離網)
而(er)離網輸(shu)(shu)出端(back-up輸(shu)(shu)出端),Back-up端輸(shu)(shu)出電(dian)壓為220/230V,只(zhi)能接負(fu)載,對于常見的負(fu)載都可以(yi)接入,負(fu)載功(gong)(gong)率受到逆變器功(gong)(gong)率的限制(zhi),一(yi)般5kW(GW5048D-ES)逆變器離網端最大輸(shu)(shu)出不(bu)超過4.6kW,接單個感性負(fu)載不(bu)超過1.5kW,總的感性負(fu)載不(bu)超過2.5kW。
同時還必須注意(yi)以下事項:離(li)網(wang)端(duan)不能(neng)和并網(wang)端(duan)接在一(yi)起(qi)。多臺儲能(neng)機的離(li)網(wang)端(duan)也不能(neng)接在一(yi)起(qi)。
在備用模式下(xia),back-up由電(dian)網供(gong)電(dian),突然(ran)電(dian)網斷(duan)電(dian)會自動切換(huan)(huan)到(dao)電(dian)池供(gong)電(dian),并離網切換(huan)(huan)時(shi)(shi)間小于(yu)10ms,UPS級別響應(ying)時(shi)(shi)間,屬(shu)于(yu)不間斷(duan)電(dian)源;而很多逆(ni)(ni)變(bian)(bian)器(qi)廠家的儲能逆(ni)(ni)變(bian)(bian)器(qi)為EPS,屬(shu)于(yu)應(ying)急電(dian)源,切換(huan)(huan)時(shi)(shi)間只是(shi)小于(yu)5s。
5、通訊情況
1接BMS協(xie)議通訊,逆變器自帶3m的通訊線,默認CAN通訊;
2為DRED接口(kou),澳(ao)洲電網要(yao)求;
3為RS485接口,可做第三(san)方監控;
4為預留接口。
WiFi模塊(kuai)可實現本地配置(zhi),逆變器(qi)沒有按鍵和顯示屏,需要通過手(shou)機APP或平板連接逆變器(qi)的solar-wifi進行(xing)相關工作模式的設置(zhi),同(tong)時WiFi還可以(yi)像(xiang)并網機一樣可實現遠程(cheng)監(jian)控。
Ezmeter口(kou)接Ezmeter表,線長10m,電(dian)表通訊(xun)為(wei)RS485通訊(xun)Ezmeter表可(ke)監(jian)測本地負載(zai)的情況,還可(ke)以實現防(fang)逆流的功能(不往(wang)電(dian)網送電(dian))。
6、基本參數
散熱(re)方式——無風扇,自然散熱(re),超靜音(yin)(<25dB),低損耗;
安(an)裝(zhuang)方(fang)式—壁掛式安(an)裝(zhuang),含背(bei)板。
防護等級——IP65(可以戶(hu)外(wai)安(an)裝(zhuang)使(shi)用(yong))
人機交互—LED燈(deng)(deng),APP控制,逆變器上(shang)共(gong)有8個LED等,分(fen)別代表SYSTEM、BACK-UP、SOLAR、BATTERY、GRID、ENERGY、WIFI、FAULT,每(mei)個燈(deng)(deng)含義(yi)如下:
7、逆變器效率
逆變器(qi)的效率(lv)是(shi)(shi)很重要的,同時逆變器(qi)的穩定性、保(bao)護、電(dian)磁(ci)干擾(rao)能力(li)、輸出電(dian)壓冗余、短時過載能力(li)、諧(xie)波諧(xie)振也是(shi)(shi)非常重要的,為(wei)此國家或(huo)者行業制定了(le)相關(guan)法規和(he)標準(zhun)。
8、法規及標準
逆(ni)變器要并(bing)到當地(di)電網,必須符合當地(di)的并(bing)網標(biao)準(zhun),安全標(biao)準(zhun)和EMC標(biao)準(zhun);目前國內暫(zan)時還沒有關(guan)于儲能的標(biao)準(zhun),并(bing)網的標(biao)準(zhun)對儲能逆(ni)變器有諸多(duo)不適用。期待關(guan)于儲能的法(fa)規和補貼能夠早日到來。