【吊(diao)頂(ding)施(shi)工(gong)(gong)】硅(gui)鈣(gai)板(ban)吊(diao)頂(ding)施(shi)工(gong)(gong)工(gong)(gong)藝 硅(gui)鈣(gai)板(ban)吊(diao)頂(ding)施(shi)工(gong)(gong)流程
硅鈣板吊(diao)頂主要優(you)點是質輕、防(fang)水、吸(xi)聲,施(shi)工(gong)簡單,這使(shi)得硅鈣板吊(diao)頂近幾年來頗受人們青睞。那(nei)么硅鈣板吊(diao)頂施(shi)工(gong)工(gong)藝(yi)及流程怎樣(yang)的呢(ni)?接下來就讓我(wo)們來了(le)解(jie)下吧!
1、彈線:
根據事先(xian)從標高點引出的標高彈(dan)出50cm控(kong)制線(xian)(xian),并依據彈出(chu)的控(kong)制線(xian)(xian)確定各房(fang)間吊頂設計標高(gao)的標準線(xian)(xian)。在墻上劃出(chu)龍骨的分(fen)檔(dang)控(kong)制點,一(yi)般距離(li)900-1200mm左右。
2、安裝吊筋:
根據施工大樣圖(tu)紙要求確(que)定(ding)吊(diao)筋(jin)(jin)的(de)位置,安裝吊(diao)筋(jin)(jin)前,刷(shua)防銹漆。吊(diao)桿采用直徑(jing)為Φ6的鋼筋制作(zuo)并刷防銹漆,吊(diao)點(dian)間(jian)距900-1200mm。安裝時(shi)上(shang)端(duan)(duan)與鐵(tie)脹(zhang)栓連接(jie),下端(duan)(duan)套絲后(hou)與吊件(jian)連接(jie)。安裝完(wan)畢(bi)的吊桿(gan)端(duan)(duan)頭外露長度不小(xiao)于3MM。
3、安裝主龍骨:
采用UC50或U38龍骨,吊頂主龍骨間距為(wei)小于1200MM。安裝主龍(long)骨(gu)(gu)時,應將主龍(long)骨(gu)(gu)吊(diao)掛件連接在(zai)主龍(long)骨(gu)(gu)上,擰緊螺絲,并根據設(she)計(ji)要(yao)求吊(diao)頂起拱 ,起拱高度約為(wei)短跨的1/200,并且安裝的(de)主龍(long)骨接長應(ying)錯(cuo)開,在(zai)接頭處(chu)增加吊點,隨時(shi)檢查龍(long)骨的(de)平(ping)整度。當遇到(dao)通風管道(dao)較大(da)超過龍(long)骨最大(da)間距要求時(shi),必須采用30*3以上的(de)角鋼做龍(long)骨骨架(jia),并(bing)且(qie)不能將(jiang)骨架(jia)與(yu)通風(feng)管道等(deng)設備工程接觸(chu)。
4、安裝次龍骨:
按照(zhao)面板的不(bu)同安裝方式和規格,次龍骨分(fen)為T形和(he)C形兩種,次龍骨(gu)間(jian)距為600mm,將次龍骨通過掛(gua)件吊掛(gua)在(zai)大(da)龍骨上,在(zai)與主(zhu)龍骨平行方向安(an)裝600MM的橫撐龍骨(gu),間距為600MM或1200MM。當采(cai)用擱置法(fa)和(he)企(qi)口法(fa)安裝時次龍骨為T形,粘(zhan)貼法(fa)或(huo)者(zhe)其(qi)他固定(ding)法(fa)時選用C形。
5、安裝邊龍(long)骨:采用L型(xing)邊龍(long)骨(gu),與墻(qiang)體用塑料脹(zhang)管或自攻螺釘固(gu)定(ding),固(gu)定(ding)間(jian)距200MM。安裝邊龍骨前墻(qiang)面應用膩子找(zhao)平(ping),可(ke)以避免將來墻(qiang)面刮膩子時污(wu)染(ran)和(he)不易找(zhao)平(ping)。
6、安裝“T” 龍骨:
在龍骨安裝時,在燈具和(he)風口位置的周邊加設“T”型加強(qiang)龍骨。
7、隱蔽檢查:
在水(shui)(shui)電(dian)安(an)裝、試(shi)水(shui)(shui)、打(da)壓完畢后,應對龍(long)骨進行隱蔽(bi)檢查,合格(ge)后方可進入下道工序。
8、安裝硅鈣板:
硅鈣板規格、厚度根(gen)據設計要求確(que)定,安裝時(shi)操作(zuo)工人須戴白手套,以防止污(wu)染(ran)。