電梯門系統故障集錦 電梯維修基礎知識
裝有自動門的電梯,門系統經常會產生各種故障,影響電梯的正常運行。現以當前大量使用的XPM電梯為例。
1. 電梯既不能關門,又不能開門。
檢修和(he)排除方法:①控制電(dian)(dian)路(lu)(lu)熔(rong)(rong)斷器1RD、2RD或(huo)門(men)(men)機電(dian)(dian)路(lu)(lu)熔(rong)(rong)斷器11RD過松(song)(song)或(huo)熔(rong)(rong)斷,擰(ning)緊(jin)或(huo)更(geng)換(huan);②門(men)(men)機傳(chuan)動(dong)皮帶(dai)打(da)滑(hua),張緊(jin)皮帶(dai)或(huo)更(geng)換(huan);③門(men)(men)機電(dian)(dian)動(dong)機DM損壞,用(yong)萬(wan)用(yong)表M3、M4之間直流(liu)電(dian)(dian)壓為110V,而門(men)(men)機不(bu)轉,說(shuo)明電(dian)(dian)動(dong)機損壞,加(jia)以(yi)修復(fu)或(huo)更(geng)換(huan);④門(men)(men)機電(dian)(dian)阻RMD斷絲(si)不(bu)通,更(geng)換(huan)電(dian)(dian)阻RMD;⑤門(men)(men)機電(dian)(dian)路(lu)(lu)個別(bie)連(lian)接(jie)端(duan)點(M1或(huo)M2或(huo)M3或(huo)M4)松(song)(song)動(dong)脫落,擰(ning)緊(jin)使線路(lu)(lu)暢通;⑥在基站(zhan)用(yong)鑰匙無法開(kai)(kai)、關門(men)(men),如果(guo)將(jiang)22、24點短(duan)接(jie),電(dian)(dian)梯(ti)(ti)關門(men)(men)或(huo)將(jiang)22、32短(duan)接(jie),電(dian)(dian)梯(ti)(ti)開(kai)(kai)門(men)(men),說(shuo)明廳外(wai)鑰匙開(kai)(kai)關DYK接(jie)點接(jie)觸不(bu)良(liang)或(huo)折(zhe)斷。若(ruo)接(jie)觸不(bu)良(liang),可用(yong)無水酒(jiu)精清洗,并調(diao)整接(jie)點彈簧片;若(ruo)接(jie)點折(zhe)斷,則更(geng)換(huan)DYK。
2. 到站平層后,電梯門不開。
檢修和排除方法:①二級開(kai)(kai)門限(xian)位開(kai)(kai)關2KM損壞,使(shi)開(kai)(kai)門繼(ji)(ji)電(dian)器(qi)(qi)JKM不能(neng)得電(dian),電(dian)梯無法開(kai)(kai)門。短接兩點(dian)38、01檢查確定,能(neng)開(kai)(kai)門,說明2KM損壞,更(geng)換(huan)2KM;②繼(ji)(ji)電(dian)器(qi)(qi)JKM損壞,更(geng)換(huan)JKM;③開(kai)(kai)門電(dian)氣(qi)回路(lu)出現(xian)故障,如運行繼(ji)(ji)電(dian)器(qi)(qi)JYT常閉接點(dian)不通等,給予排除;④開(kai)(kai)門區(qu)域永磁繼(ji)(ji)電(dian)器(qi)(qi)(俗稱干(gan)簧管)損壞,使(shi)開(kai)(kai)門控制繼(ji)(ji)電(dian)器(qi)(qi)JMQ不能(neng)吸(xi)合,其常開(kai)(kai)觸點(dian)仍斷開(kai)(kai),繼(ji)(ji)電(dian)器(qi)(qi)JKM無法得電(dian),而(er)不能(neng)開(kai)(kai)門,更(geng)換(huan)開(kai)(kai)門區(qu)域永磁繼(ji)(ji)電(dian)器(qi)(qi)。
3. 按下關門按鈕,門不關。
檢(jian)修和排除(chu)方(fang)法(fa):①關門按(an)鈕(niu)AGM接(jie)點接(jie)觸不(bu)良(liang)或(huo)損壞(huai),短接(jie)兩(liang)點23、24檢(jian)查測(ce)定,然后修復或(huo)更(geng)換;②三級關門限位開關3GM損壞(huai),使關門繼(ji)電(dian)(dian)器(qi)(qi)(qi)JGM不(bu)能得電(dian)(dian),電(dian)(dian)梯(ti)無法(fa)關門,短接(jie)28、01兩(liang)點檢(jian)查測(ce)定,能關門,說明3GM損壞(huai),更(geng)換3GM;③關門繼(ji)電(dian)(dian)器(qi)(qi)(qi)JGM損壞(huai),更(geng)換JGM;④啟(qi)動(dong)開門繼(ji)電(dian)(dian)器(qi)(qi)(qi)1JQ損壞(huai),其(qi)常開觸點1JQ仍斷開,JGM無法(fa)得電(dian)(dian),因而不(bu)能關門,更(geng)換繼(ji)電(dian)(dian)器(qi)(qi)(qi)1JQ。
4.電梯已接受選層信號,門關閉,但不能起動。
檢修(xiu)和排(pai)除方法:①轎(jiao)門(men)閉(bi)合到位,但轎(jiao)門(men)聯鎖(suo)(suo)開關(guan)(guan)KMJ未接通,門(men)鎖(suo)(suo)繼電器JMS不(bu)能得電,因(yin)而(er)不(bu)能起(qi)動,調整或更(geng)換(huan)開關(guan)(guan)KMJ;②廳門(men)未關(guan)(guan)閉(bi)到位,廳門(men)聯鎖(suo)(suo)開關(guan)(guan)KMT未能接通,門(men)鎖(suo)(suo)繼電器JMS不(bu)能得電,因(yin)而(er)不(bu)能起(qi)動,重新開關(guan)(guan)門(men),如不(bu)奏效,應(ying)調整門(men)速或門(men)鎖(suo)(suo)開關(guan)(guan)KMT;③門(men)關(guan)(guan)到位,但門(men)鎖(suo)(suo)開關(guan)(guan)KMT出(chu)現故障(zhang),排(pai)除或更(geng)換(huan)門(men)鎖(suo)(suo);④運行繼電器JYT出(chu)現故障(zhang),修(xiu)復或更(geng)換(huan)JYT。
5.門未關,電梯能選層啟動。
檢修和(he)排(pai)除(chu)方法:①門(men)鎖繼電器JMS有卡阻常吸不(bu)放,排(pai)除(chu)和(he)更換繼電器JMS;②門(men)鎖開關(guan)KMT觸頭粘連(微動開關(guan)的門(men)鎖),排(pai)除(chu)或更換門(men)鎖。
6.電梯在行駛途中突然停車。
檢(jian)修和排除方(fang)法:門刀(dao)碰撞門輪(lun),使鎖臂脫(tuo)開,門鎖開關KMT斷(duan)開,門鎖繼電器JMS失電,電梯立即停車(che),調整(zheng)門鎖滾(gun)輪(lun)與門刀(dao)位置。
7.開門速度無變速。
檢(jian)修和(he)排除方法:①開(kai)(kai)(kai)門一級(ji)限位開(kai)(kai)(kai)關1KM損壞,更(geng)換(huan)開(kai)(kai)(kai)關1KM;②開(kai)(kai)(kai)門分路電阻RKM斷(duan)絲不(bu)通(tong),更(geng)換(huan)電阻RKM。
8.關門速度無變速。
檢修(xiu)和排除方(fang)法:①關(guan)(guan)門一、二級限位開(kai)關(guan)(guan)1GM、2GM損壞,更換1GM、2GM;②關(guan)(guan)門分路電阻RGM斷絲不通,更換電阻RGM。
9.開關門速度變慢
檢(jian)修和(he)排除方法(fa):開門機皮帶(dai)打滑,張緊(jin)皮帶(dai)。
10.開關門時門扇振動大。
檢修和排除方法:①門(men)(men)(men)滑(hua)輪磨損嚴重,更換(huan)門(men)(men)(men)滑(hua)輪;②門(men)(men)(men)導軌(gui)變形或(huo)(huo)發生松動(dong)偏斜,校正門(men)(men)(men)導軌(gui),調(diao)整、緊(jin)固導軌(gui);③地坎中(zhong)的滑(hua)槽積塵過多(duo)或(huo)(huo)有雜物,妨礙門(men)(men)(men)的滑(hua)行(xing),應清理滑(hua)槽;④門(men)(men)(men)鎖兩個滾輪與門(men)(men)(men)刀未緊(jin)貼,間隙大,調(diao)整門(men)(men)(men)鎖。