一、消防滅火系統有哪幾種
消防滅火系統(tong)類(lei)型一般分(fen)為:火災(zai)自動報警系統(tong)、氣體(ti)滅火系統(tong)、泡沫滅火系統(tong)、防排煙系統(tong)、消防栓(shuan)系統(tong)、滅火器配置、自動噴水滅火系統(tong)、火災(zai)應急(ji)照明和(he)疏散(san)指示(shi)標志。
這些(xie)消防滅火系統一般都(dou)用(yong)在住宅(zhai)、配電(dian)室(shi)、樓梯間(jian)、走道、地下車(che)庫等建筑物,幾乎(hu)所有建筑物都(dou)要(yao)安裝。
二、消防滅火系統工作原理是什么
1、自動報警系統的工作原理
火(huo)(huo)(huo)災(zai)(zai)自(zi)動(dong)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)系統(tong)應由觸發(fa)裝置、災(zai)(zai)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)裝置、災(zai)(zai)警(jing)(jing)(jing)(jing)報(bao)(bao)(bao)裝置和(he)電源等四部(bu)分組成,火(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)大致過(guo)(guo)程:當(dang)煙、溫度(du)、光、氣(qi)體(ti)濃度(du)等火(huo)(huo)(huo)場(chang)參數超(chao)過(guo)(guo)某一給定閾值時,火(huo)(huo)(huo)災(zai)(zai)探(tan)測器(qi)動(dong)作(zuo)(zuo),發(fa)出(chu)(chu)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)號,該(gai)信號經過(guo)(guo)連(lian)接導線傳(chuan)送至區域火(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)控制器(qi)和(he)(或)集中火(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)控制器(qi),發(fa)出(chu)(chu)聲、光報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)信號,同時顯示火(huo)(huo)(huo)災(zai)(zai)發(fa)生的(de)(de)部(bu)位,以通(tong)知消防值班人員做出(chu)(chu)反應,這也就是(shi)我們通(tong)常所說的(de)(de)火(huo)(huo)(huo)災(zai)(zai)自(zi)動(dong)報(bao)(bao)(bao)警(jing)(jing)(jing)(jing)系統(tong)的(de)(de)工作(zuo)(zuo)原理。
2、防排煙系統的工作原理
當發(fa)生災后,操作機(ji)(ji)構在煙感報警電(dian)信號作用下,將(jiang)風閥(fa)自動(dong)打開,并啟(qi)(qi)動(dong)送(song)(song)風機(ji)(ji)與排(pai)煙風機(ji)(ji),當排(pai)煙管(guan)內的氣(qi)流達到280°C時,管(guan)道防(fang)火閥(fa)熔斷器熔斷。關(guan)閉防(fang)火閥(fa),關(guan)閉信號通過輸入模塊發(fa)送(song)(song)至控(kong)(kong)制器,自動(dong)或手動(dong)啟(qi)(qi)動(dong)相應控(kong)(kong)制模塊去關(guan)閉排(pai)煙機(ji)(ji)。
在有空調設備時,空調送風管道內的氣流溫(wen)度達(da)到70°C時,防火(huo)(huo)熔斷器動(dong)作(zuo),關(guan)閉(bi)防火(huo)(huo)閥(fa),關(guan)閉(bi)信(xin)號通(tong)過輸入模塊傳送至控制器,控制器則根據聯動(dong)關(guan)系給(gei)控制模塊信(xin)號,關(guan)閉(bi)空調機。
3、泡沫系統的工作原理
(1)閉式泡沫噴淋滅火系統工作原理
當有火災(zai)發生時,閉式(shi)噴頭(tou)的玻璃球破裂(lie)噴水,水流(liu)指示器、濕式(shi)報警(jing)閥動(dong)作,有信號(hao)傳至控制柜(ju),此時,手動(dong)或自動(dong)開啟消防泵比(bi)例混(hun)合裝置上的電磁(ci)閥及管路閥門(men),系統工作。一定(ding)壓(ya)力的消防水經泡沫(mo)比(bi)例混(hun)合裝置與泡沫(mo)液混(hun)合,形成(cheng)一定(ding)比(bi)例的泡沫(mo)混(hun)合液,經噴頭(tou)生成(cheng)空氣泡沫(mo)滅火。
系統組成(cheng):閉式泡(pao)沫(mo)噴淋滅火系統主要(yao)由消防水(shui)泵泡(pao)沫(mo)比例(li)混(hun)合(he)裝(zhuang)置、閉式噴頭、水(shui)流指(zhi)示器、濕式報警閥及其(qi)它閥門、管道(dao)等組成(cheng)。
(2)開式泡沫噴淋滅火系統的工作原理
當有火災(zai)發生(sheng)時,安裝于保護(hu)區的火災(zai)探測器有信號(hao)傳至(zhi)控制柜,此時,手動或自(zi)動開啟(qi)雨(yu)淋閥、消防泵比例混(hun)合(he)器上的電磁閥及管路閥門,系統工作。壓力消防水經泡(pao)沫比例混(hun)合(he)裝置與泡(pao)沫液(ye)混(hun)合(he),形成一(yi)定比例的泡(pao)沫混(hun)合(he)液(ye),經噴頭(tou)生(sheng)成空氣泡(pao)沫滅(mie)火。
系統組(zu)成:開式泡(pao)(pao)沫噴(pen)淋(lin)滅火系統主(zhu)要由消防水泵、泡(pao)(pao)沫比例混合裝置、開式噴(pen)頭、雨淋(lin)閥(fa)(fa)及(ji)其它閥(fa)(fa)門、管(guan)道等組(zu)成。
4、室內外消火栓系統的工作原理
消火(huo)栓開啟(qi),有(you)水噴出(chu),恒壓(ya)泵啟(qi)動,恒壓(ya)對管網補壓(ya),按下(xia)破(po)玻(bo)按鈕(niu),消防(fang)中心收(shou)到破(po)玻(bo)按鈕(niu)報警信號,警鈴鳴(ming)響,直(zhi)接(jie)啟(qi)動主(zhu)消防(fang)水泵,消防(fang)水泵對管網進行(xing)加壓(ya),消火(huo)栓上的啟(qi)泵指示燈亮。消防(fang)中心收(shou)到消防(fang)水泵運行(xing)信號。
因水泵壞(huai)或水池無水時,消(xiao)防車對(dui)水泵接合器進行(xing)加壓,保證(zheng)消(xiao)防系統能(neng)正(zheng)常運行(xing)。(水泵能(neng)手(shou)動啟(qi)動,消(xiao)防中心(xin)手(shou)動啟(qi)動、自動啟(qi)動)。
5、噴淋自動滅火系統的工作原理
噴(pen)(pen)淋(lin)頭達(da)到(dao)額(e)定溫(wen)度時,玻璃內(nei)的液體發熱(re)膨脹,玻璃管破碎,噴(pen)(pen)淋(lin)頭噴(pen)(pen)水(shui),水(shui)流指示(shi)器報(bao)警(jing)(jing),消(xiao)防(fang)中心(xin)收(shou)到(dao)報(bao)警(jing)(jing)信號(hao),力下(xia)降,水(shui)池(chi)或恒壓(ya)(ya)泵(beng)(beng)補壓(ya)(ya),濕式報(bao)警(jing)(jing)閥(fa)動(dong)(dong)作,水(shui)力警(jing)(jing)鐘鳴響,壓(ya)(ya)力開關報(bao)警(jing)(jing),消(xiao)防(fang)中心(xin)收(shou)報(bao)警(jing)(jing)信號(hao),水(shui)泵(beng)(beng)起泵(beng)(beng)加(jia)(jia)壓(ya)(ya)。消(xiao)防(fang)中心(xin)收(shou)到(dao)噴(pen)(pen)淋(lin)泵(beng)(beng)運(yun)行(xing)(xing)信號(hao)。因水(shui)泵(beng)(beng)壞或水(shui)池(chi)無(wu)水(shui)時,消(xiao)防(fang)車對水(shui)泵(beng)(beng)接合器進行(xing)(xing)加(jia)(jia)壓(ya)(ya),保證(zheng)消(xiao)防(fang)系統能(neng)(neng)正(zheng)常運(yun)行(xing)(xing)。(水(shui)泵(beng)(beng)能(neng)(neng)手動(dong)(dong)啟動(dong)(dong),消(xiao)防(fang)中心(xin)手動(dong)(dong)啟動(dong)(dong)、自動(dong)(dong)啟動(dong)(dong))。
6、氣體自動滅火系統的工作原理
感煙(yan)(yan)或(huo)感溫探測器(qi)任一報(bao)(bao)警,主機收(shou)到(dao)信(xin)號,警鐘(zhong)鳴響,感煙(yan)(yan)與感溫探測器(qi)同(tong)時報(bao)(bao)警,主機收(shou)到(dao)信(xin)號,警鐘(zhong)鳴響,光報(bao)(bao)警器(qi)鳴響。30S后聯(lian)動風閥、停(ting)空調(diao)新風機等、啟動氣體進行滅火(huo)(因誤(wu)報(bao)(bao)時在(zai)30S內(nei)按(an)下門口或(huo)主機上(shang)的急停(ting)按(an)鈕停(ting)止放(fang)氣)。人(ren)員發現(xian)火(huo)災(zai)時,直(zhi)接(jie)按(an)下門口或(huo)主機上(shang)的緊急放(fang)氣按(an)鈕,直(zhi)接(jie)聯(lian)動風閥、停(ting)空調(diao)新風機等啟動氣體進行滅火(huo)。
因(yin)主機不能正(zheng)常啟動氣體(ti)滅火(huo)時,直按(an)用機械啟動氣體(ti)進行(xing)滅火(huo)。
7、防火卷簾的工作原理
在(zai)火(huo)災發(fa)生時(shi)起(qi)防(fang)火(huo)分區隔斷作(zuo)用,在(zai)火(huo)災發(fa)生時(shi),感(gan)煙探測(ce)器(qi)報(bao)(bao)(bao)警,災信(xin)號送(song)到卷(juan)(juan)簾(lian)(lian)門(men)(men)制柜,控制柜發(fa)出啟動(dong)(dong)信(xin)號,卷(juan)(juan)簾(lian)(lian)門(men)(men)自(zi)動(dong)(dong)降(jiang)到距(ju)地(di)1。8米(mi)的(de)位(wei)置(特殊部(bu)位(wei)的(de)卷(juan)(juan)簾(lian)(lian)門(men)(men)也可(ke)一步到底),如(ru)果感(gan)溫(wen)探測(ce)器(qi)再報(bao)(bao)(bao)警,卷(juan)(juan)簾(lian)(lian)門(men)(men)才降(jiang)到底。報(bao)(bao)(bao)警狀態(tai)時(shi),人員可(ke)手動(dong)(dong)按住上行按鈕升起(qi)卷(juan)(juan)簾(lian)(lian),人過去后放(fang)開按鈕后防(fang)火(huo)門(men)(men)又(you)自(zi)動(dong)(dong)下行。
8、消防廣播的工作原理
當火(huo)災(zai)發生時,災(zai)區(qu)域/層(ceng)(如n層(ceng))的消防煙感(gan)溫感(gan)等(deng)探(tan)測(ce)器發出報警動(dong)(dong)作信號,消防接收控制(zhi)盤、邏(luo)輯控制(zhi)等(deng)消防聯動(dong)(dong)裝置自動(dong)(dong)(或(huo)手動(dong)(dong))啟動(dong)(dong),通過消防發送控制(zhi)盤發出驅動(dong)(dong)和切換控制(zhi)信號。
一(yi)路去啟動(dong)消防(fang)廣播(bo)錄放(fang)盤,該盤可(ke)(ke)選擇播(bo)音(yin)(yin)(yin)卡播(bo)音(yin)(yin)(yin)或話筒播(bo)音(yin)(yin)(yin)作(zuo)為緊(jin)急廣播(bo),并可(ke)(ke)自動(dong)錄音(yin)(yin)(yin)。
9、恒壓泵的工作原理
當(dang)管網泄漏、系(xi)(xi)統壓(ya)力(li)降至設定壓(ya)力(li)下(xia)限(xian)時,穩壓(ya)水(shui)泵(beng)自動(dong)(dong)啟動(dong)(dong),對管網進(jin)行補(bu)壓(ya),以供消(xiao)防供水(shui)系(xi)(xi)統保(bao)證最不利點的消(xiao)防所需(xu)壓(ya)力(li),當(dang)系(xi)(xi)統壓(ya)力(li)達到設定壓(ya)力(li)上限(xian)時穩泵(beng)停(ting)止工(gong)作,每(mei)次(ci)壓(ya)力(li)下(xia)降時,都重復上述遠行過程(cheng),以穩定消(xiao)防管網的壓(ya)力(li)。
消防用(yong)水時(shi),穩壓(ya)(ya)(ya)泵(beng)持續(xu)運(yun)行(xing)阻懷壓(ya)(ya)(ya)力的下降,當力降到消防主(zhu)泵(beng)啟動(dong)(dong)壓(ya)(ya)(ya)力時(shi),電控(kong)系統(tong)發(fa)出(chu)報警(jing)信號,啟動(dong)(dong)消防主(zhu)泵(beng)進行(xing)供水,當消防主(zhu)泵(beng)運(yun)行(xing)到達額定流量種壓(ya)(ya)(ya)力時(shi),控(kong)制系統(tong)關閉主(zhu)泵(beng)穩壓(ya)(ya)(ya)水運(yun)行(xing),當單臺消防泵(beng)運(yun)行(xing)機制信用(yong)證阻止(zhi)不住壓(ya)(ya)(ya)力下降,系統(tong)壓(ya)(ya)(ya)力降至(zhi)消防最低壓(ya)(ya)(ya)力時(shi),消防備用(yong)泵(beng)啟動(dong)(dong)(有兩(liang)主(zhu)一備時(shi))。